Representative Image

Vacuubrand ME 4C NT Chemistry Diaphragm Pump, One-Stage, 230 V / 50 Hz, with CH Plug

Plug type

Specifications

Compare models
Depth
254 mm
Dimensions (WxDxH)
243 x 254 x 198 mm
Flow rate
3.9 m³/h
Height
198 mm
No. of stages
1
Plug type
CH
Type
ME 4C NT
Ultimate vacuum
70 mbar
UNSPSC
40151502
Width
243 mm

Alternative in-stock items

NTD 111,647

Inc. VAT

Available soon

Product description

The Vacuubrand ME 4C NT is a high-performance, single-stage diaphragm pump designed for continuous, oil-free evacuation and pumping of corrosive gases and vapors in laboratory settings. Operating at 230 V with a frequency of 50 Hz, this pump comes equipped with a CH plug for seamless integration into your laboratory infrastructure.

Key Features:

  • Brand: Vacuubrand
  • Type: Single-stage diaphragm pump for high-performance vacuum generation
  • Voltage: 230 V
  • Frequency: 50 Hz
  • Plug Type: CH plug for easy connection
  • Ultimate Vacuum: 70 mbar (52 torr)
  • Max. Pumping Speed at 50 Hz: 3.9 m³/h
  • Number of Heads: 2
  • Number of Stages: 1
  • Inlet Connection: Hose nozzle DN 8–10 mm
  • Outlet Connection: Hose nozzle DN 8–10 mm
  • Rated Motor Power: 0.18 kW
  • Rated Motor Speed at 50 Hz: 1500 min⁻¹
  • Protection Class (IEC 60529): IP 40
  • Dimensions (L x W x H): 254 mm x 243 mm x 198 mm
  • Weight: 11.1 kg
  • Noise Level: 45 dBA
  • ATEX Conformity: II 3G IIC T3 X (Internal Atm. only)

This diaphragm pump is an essential tool for laboratories that require a dependable, efficient vacuum pump for a wide range of chemical and sample processing applications. Its robust construction and high chemical resistance make it suitable for demanding environments.

Accessories

Sealing kit NT for chemistry diaphragm pumps NT

ProductForUNSPSCMfr#Part#AvailabilityPrice
MZ 2C NT40151502206968696.241 476NTD 13,509
MD 4C NT40151502206968706.239 489NTD 25,754
ME 4 NT, MZ 2 NT40151502206968609.880 902NTD 7,368
ME 4C NT40151502206968649.880 906NTD 7,838
MZ 2D NT40151502206968639.880 904NTD 7,368
MV 2 NT / MD 4 NT40151502206968619.880 905NTD 13,039
ME 8 NT40151502206968629.880 903NTD 10,764
ME 8C NT40151502206968679.880 907NTD 15,243

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081NTD 3,973
PVC34.9 mm206860634.714 084NTD 10,114
PVC38.1 mm206860654.714 085NTD 11,811
PVC15.9 mm206860614.714 082NTD 4,659
PVC22.3 mm206860624.714 083NTD 5,526

Compare similar models

Chemistry diaphragm pump ME 4C NT one-stage, 230 V~ 50 Hz plug CH

Manufacturer P/N

20731201

Part Number

9.880 895

Manufacturer

VACUUBRAND​

Plug type

CH

Chemistry diaphragm pump ME 4C NT one-stage, 230 V~ 50 Hz plug CEE

Manufacturer P/N

20731200

Part Number

9.880 894

Manufacturer

VACUUBRAND​

Plug type

EU

Chemistry diaphragm pump ME 4C NT, one stage, certification (NRTL): C/US230 V / 50-60 Hz, UK/IN mains cable

Manufacturer P/N

20731202

Part Number

4.670 425

Manufacturer

VACUUBRAND​

Plug type

UK

Chemistry diaphragm pump ME 4C NT, one stage, certification: (NRTL): C/US100-115 V / 50-60 Hz, 120 V / 60 Hz, US mains cable

Manufacturer P/N

20731203

Part Number

4.670 426

Manufacturer

VACUUBRAND​

Plug type

US

More items to explore

Diaphragm pumps chemistry design, ME 1C

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUME 1C207211009.880 934In stockNTD 51,146
UKME 1C207211029.880 936NTD 51,146
CHME 1C207211019.880 935NTD 51,146
USME 1C207211039.880 937NTD 51,146

Frequently asked questions

It is a high-performance, single-stage diaphragm pump designed for continuous, oil-free evacuation and pumping of corrosive gases and vapors in laboratory settings. Operating at 230 V with a frequency of 50 Hz, this pump comes equipped with a CH plug for seamless integration into your laboratory infrastructure.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 111,647

Inc. VAT