Xylem WTW OxiTop-IDS AN6, 100–240 VAC, 50/60 Hz – Respirometric Measuring System, 6 Measuring Points, Including Stirring Platform IS-6 VAR

Brand:Xylem WTW

No. of measuring positions

Nominal volume bottle

Type

Specifications

Compare models
Power supply frequency
50/60 Hz
Max. measured value
4000 mg/l
Max. pressure
1500 hPa
Max. voltage
240 V
Measured range
0 ... 4,000 mg/l
Measuring time
180 d
Min. measured value
0 mg/l
Min. pressure
500 hPa
Min. voltage
100 V
No. of measuring positions
6

NTD 367,810

Inc. VAT

Available soon

Product description

The Xylem WTW OxiTop-IDS AN6 is a high-performance respirometric measuring system designed for the determination of aerobic respiration. This compact setup supports up to 6 measuring points and includes the IS-6 VAR stirring platform, optimized for sample bottles with a larger diameter. Ideal for environmental and laboratory analysis, the system features integrated sensors and Bluetooth connectivity for wireless data handling.

Key Features:

  • Brand: Xylem WTW
  • Model: OxiTop-IDS AN6
  • Power Supply: 100–240 VAC, 50/60 Hz for global compatibility
  • Measuring Points: 6 fully integrated measuring channels
  • Stirring Platform: IS-6 VAR platform suitable for larger sample bottles
  • Application: Determination of aerobic respiration in environmental and biological samples
  • Note: CO₂ absorber NHP 600 and IDS multi-parameter measuring instruments (Multi 3620 IDS Set WL or Multi 3630 IDS Set WL) are required and must be ordered separately

Scope of Supply:

  • 6 x OxiTop-IDS/B measuring heads
  • 6 x sample bottles MF45/1000 (1000 ml)
  • Nitrification inhibitor
  • 6 x magnetic stirring bars
  • Stirring bar retriever
  • 1 x stirring platform IS-6 VAR

This Xylem WTW OxiTop-IDS AN6 system ensures reliable, real-time data collection and is an excellent solution for labs requiring precision and scalability in respirometric testing.

Downloads

Accessories

Stirring platforms OxiTop® for BOD measurement

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
IS 6Mains connection2081407.057 185NTD 62,054
IS 12Mains connection2081417.091 025NTD 84,051
IS 6-VarMains connection2081457.602 857NTD 103,412

Wireless measuring heads OxiTop® IDS

Compare similar models

OxiTop®-IDS AN6, 100 - 240 VAC, 50/60 Hz Respirometric measuring system, 6 measuring pts incl. stirring platform IS 6-VAR

Manufacturer P/N

209725

Part Number

6.314 044

Manufacturer

Xylem WTW

No. of measuring positions

6

Respirometric measuring system OxiTop®-IDS AN12 f. anaerobic measuring operation, 12 measuring pts 12 sample bottles MF45/250 (250 ml), each with two

Manufacturer P/N

209727

Part Number

6.314 045

Manufacturer

Xylem WTW

No. of measuring positions

12

More items to explore

BOD Measuring system OxiTop®-IDS B6 for determination of soil respiration

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
OxiTop ® -IDS B6Battery2097296.314 046NTD 236,008

Frequently asked questions

It is a high-performance respirometric measuring system designed for the determination of aerobic respiration. This compact setup supports up to 6 measuring points and includes the IS-6 VAR stirring platform, optimized for sample bottles with a larger diameter. Ideal for environmental and laboratory analysis, the system features integrated sensors and Bluetooth connectivity for wireless data handling.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 367,810

Inc. VAT