Representative Image

Vacuubrand Chemistry HYBRID Pump RC 6 230 V / 50-60 Hz, CH/CN Mains Cable

Max. voltage

Plug type

Power supply

Specifications

Compare models
Connection pressure side
DN 8-10 mm
Connection suction side
KF DN 16
Depth
302 mm
Dimensions (WxDxH)
526 x 302 x 226 mm
Flow rate
5.9 m³/h
Power supply frequency
50/60 Hz
Height
226 mm
IP code
IP 40
Max. oil filling
500 ml
Max. voltage
230 V

NTD 278,413

Inc. VAT

Available soon

Product description

The Vacuubrand Chemistry HYBRID Pump RC 6 230 V / 50-60 Hz, CH/CN Mains Cable is an advanced vacuum pump designed for high-performance applications in laboratory chemistry. Offering precise control and superior reliability, this pump is ideal for processes that require consistent vacuum levels. With a CH/CN mains cable, it ensures easy integration into laboratory setups with 230 V power supply, supporting efficient and smooth operations in various chemical processes.

Key Features:

  • Brand: Vacuubrand
  • Model: Chemistry HYBRID Pump RC 6
  • Voltage: 230 V / 50-60 Hz
  • Cable: CH/CN mains cable for easy connection
  • Application: Ideal for chemistry and laboratory vacuum applications
  • Performance: Two-stage rotary-vane pump with two-stage chemistry diaphragm for optimized corrosion resistance
  • Vacuum Range: Ultimate vacuum in the 10⁻³ mbar range
  • Maintenance: Low-maintenance design suitable for freeze-drying and other demanding processes

Scope of Supply:

  • Pump
  • Overload circuit breaker and mains cable (2 m)
  • Centering and clamping ring for inlet
  • Particulate filter
  • Operating instructions
  • Oil (bottle of 500 ml)

This Vacuubrand vacuum pump provides a reliable solution for chemistry laboratories requiring precise and stable vacuum performance across various applications.

Accessories

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081NTD 3,973
PVC34.9 mm206860634.714 084NTD 10,114
PVC38.1 mm206860654.714 085NTD 11,811
PVC15.9 mm206860614.714 082NTD 4,659
PVC22.3 mm206860624.714 083NTD 5,526

Compare similar models

Chemistry HYBRID pump RC 6 230 V / 50-60 Hz, CH/CN mains cable

Manufacturer P/N

20798561

Part Number

4.687 930

Manufacturer

VACUUBRAND​

Max. voltage

230 V

Chemistry HYBRID pump RC 6 230 V / 50-60 Hz, UK/IN

Manufacturer P/N

20798562

Part Number

4.670 386

Manufacturer

VACUUBRAND​

Max. voltage

230 V

Chemistry HYBRID pump RC 6 230 V / 50-60 Hz, CEE mains cable

Manufacturer P/N

20798560

Part Number

4.687 929

Manufacturer

VACUUBRAND​

Max. voltage

230 V

Chemical HYBRID pump RC 6 100-120 V / 50-60 Hz, US plug

Manufacturer P/N

20798563

Part Number

4.701 132

Manufacturer

VACUUBRAND​

Max. voltage

120 V

Frequently asked questions

It is an advanced vacuum pump designed for high-performance applications in laboratory chemistry. Offering precise control and superior reliability, this pump is ideal for processes that require consistent vacuum levels. With a CH/CN mains cable, it ensures easy integration into laboratory setups with 230 V power supply, supporting efficient and smooth operations in various chemical processes.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 278,413

Inc. VAT