Representative Image

Thermo Orion AquaMate AQ8100 UV-Vis Spectrophotometer

Accuracy

Illuminants

Measuring method

Scattered light

Spectral bandwidth

Type

Wavelength

Specifications

Compare models
Accuracy
±0.5 nm
Accuracy
0.5 nm
Depth
355 mm
Dimensions (WxDxH)
385 x 355 x 195 mm
Power supply frequency
50/60 Hz
Height
195 mm
Illuminants
Xenon
Interfaces
3 x USB
Max. voltage
240 V
Measuring method
UV-VIS

NTD 392,010

Inc. VAT

Available soon

Product description

Thermo Orion AquaMate AQ8100 UV-Vis Spectrophotometer

The Thermo Orion AquaMate AQ8100 UV-Vis Spectrophotometer is a highly advanced and reliable instrument designed for precise UV and visible light absorbance measurements. Featuring a wide wavelength range of 190 to 1100 nm, this spectrophotometer offers exceptional accuracy and repeatability, making it ideal for applications in chemical analysis, environmental testing, and biochemistry. With its intuitive interface and robust design, the AquaMate AQ8100 ensures reliable results and ease of use in laboratory settings.

Key Features:

  • Brand: Thermo Orion
  • Wavelength Range: 190 to 1100 nm for UV and visible light absorbance measurements
  • High Precision: Accurate and repeatable measurements for reliable analysis
  • Applications: Suitable for chemical, biological, and environmental analysis
  • Display: Easy-to-use interface with a clear LCD screen for quick result access
  • Grip & Dexterity: 260 preprogrammed test methods, with flexibility to program your own custom methods
  • Compatibility: Compatible with round, square, and rectangular vial holders
  • Compliance: Intuitive operating software including performance verification testing designed to meet GLP and GMP standards
  • Measurement Accuracy: 7-inch, high-resolution glove-friendly touchscreen interface
  • Application Focus: Designed specifically for water and wastewater analysis laboratories

Scope of Supply:

  • AQ7100 VIS: Spectrophotometer with 7-inch color touchscreen, Tungsten-Halogen lamp, 12-25 mm round vial holder, 12 x 24 mm round vials, universal power supply (EU, UK), user guide, dust cover, and USB cable
  • AQ8100 UV-VIS: Spectrophotometer with 7-inch color touchscreen, Xenon Flash Lamp, 12-25 mm round vial holder, 12 x 24 mm round vials, universal power supply (EU, UK), user guide, dust cover, and USB cable

The Thermo Orion AquaMate AQ8100 UV-Vis Spectrophotometer is a versatile and dependable solution for laboratories that require high-performance, accurate UV-Vis spectrophotometric analysis across a range of applications.

Downloads

Compare similar models

Orion-Aquamate AQ8100 UV-VIS spectrophotometer

Manufacturer P/N

AQ8100

Part Number

4.672 206

Manufacturer

Thermo Scientific

Illuminants

Xenon

Orion-Aquamate AQ7100 VIS spectrophotometer

Manufacturer P/N

AQ7100

Part Number

4.672 205

Manufacturer

Thermo Scientific

Illuminants

Tungsten-halogen

Frequently asked questions

It is a laboratory spectrophotometer or photometer used for chemical, biological, and environmental analysis. It offers a wavelength range of 190 to 1100 nm for UV and visible light absorbance measurements and an additional detail of 260 preprogrammed test methods, with flexibility to program your own custom methods.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 392,010

Inc. VAT