Representative Image

Sartorius Vivaflow 200, 0.2µm with Pressure Indicator

Brand:Sartorius

Material membrane

MWCO

Specifications

Compare models
Material membrane
PES
Membrane surface
200 cm²
Pore size
0,2 µm
UNSPSC
41104916

NTD 32,761

Inc. VAT

Available soon

Product description

The Sartorius Vivaflow 200, 0.2µm with Pressure Indicator is a high-performance crossflow filtration system designed for efficient and reliable ultrafiltration. This system is ideal for laboratory applications requiring precise sample concentration and diafiltration. The integrated pressure indicator ensures optimal monitoring for enhanced process control.

Key Features:

  • Brand: Sartorius
  • Filtration Size: 0.2µm for effective particle retention
  • Pressure Indicator: Integrated for precise monitoring
  • Application: Ideal for ultrafiltration and concentration in laboratory settings
  • Usage: Designed for high efficiency and ease of operation
  • Flow Design: Thin-channel crossflow filter units offer high crossflow rates with minimal pumping pressure
  • Scale-Up Flexibility: Modular luer connections allow interlocking in series without the need for additional fittings
  • Recovery Rate: Maximized through optimized recirculation volume and low adsorption materials

Scope of Supply

  • Crossflow filter unit
  • Pressure indicator
  • Flow restrictor
  • Tubing

With scalable performance, minimal setup requirements, and high recovery efficiency, the Sartorius Vivaflow 200 delivers exceptional filtration performance for modern lab workflows.



Frequently Asked Questions

1. What is the Sartorius Vivaflow 200, 0.2µm with Pressure Indicator used for?

It is a high-performance crossflow filtration system designed for efficient and reliable ultrafiltration. This system is ideal for laboratory applications requiring precise sample concentration and diafiltration. The integrated pressure indicator ensures optimal monitoring for enhanced process control.

2. Is this product suitable for ultrafiltration and concentration in laboratory settings?

Yes. It is designed for ultrafiltration and concentration in laboratory settings, and offers a filtration size of 0.2µm for effective particle retention to support this kind of work.

3. What filtration size does this product have?

It has a filtration size of 0.2µm for effective particle retention.

4. What pressure indicator and usage does this product offer?

It offers integrated for precise monitoring, designed for high efficiency and ease of operation, thin-channel crossflow filter units offer high crossflow rates with minimal pumping pressure and modular luer connections allow interlocking in series without the need for additional fittings.

Downloads

Accessories

Flow restrictor set

ProductDescriptionUNSPSCMfr#Part#AvailabilityPrice
Flow restrictor set41123100VF-AC-0002-V4.713 207NTD 1,084

Tubing kits for crossflow filter units Vivaflow® 50R/200

ProductDescriptionUNSPSCMfr#Part#AvailabilityPrice
Tubing kit for running two 50R cassettes in parallel41123100VF-ATP0011-14.713 211NTD 7,874
Tubing kit for running two 200 cassettes in parallel41123100VF-ATP0012-14.713 212NTD 7,874
Tubing kit for running a single cassette41123100VF-ATI0011-14.713 210NTD 6,502

Compare similar models

Vivaflow 200, 0,2µm with pressure indicator
Available soon
Sartorius Vivaflow 200, 0.2µm with Pressure Indicator

NTD 32,761

Inc. VAT

Manufacturer P/N

VF20P7

Part Number

9.049 799

Manufacturer

Sartorius

Material membrane

PES

Vivaflow 200, 5000 MWCO with pressure indicator

Manufacturer P/N

VF20P1

Part Number

9.049 794

Manufacturer

Sartorius

Material membrane

PES

Vivaflow 200, 100000 MWCO with pressure indicator

Manufacturer P/N

VF20P4

Part Number

9.049 798

Manufacturer

Sartorius

Material membrane

PES

Vivaflow 200, 50000 MWCO with pressure indicator

Manufacturer P/N

VF20P3

Part Number

9.049 797

Manufacturer

Sartorius

Material membrane

PES

Vivaflow 200, 30.000 MWCO Hydrosart
Available soon
Sartorius Vivaflow 200, 30.000 MWCO Hydrosart

NTD 32,761

Inc. VAT

Manufacturer P/N

VF20H2

Part Number

7.660 001

Manufacturer

Sartorius

Material membrane

Hydrosart®

Vivaflow 200, 10000 MWCO with pressure indicator

Manufacturer P/N

VF20P0

Part Number

9.049 795

Manufacturer

Sartorius

Material membrane

PES

Vivaflow 200, 10.000 MWCO Hydrosart
Available soon
Sartorius Vivaflow 200, 10.000 MWCO Hydrosart

NTD 32,761

Inc. VAT

Manufacturer P/N

VF20H0

Part Number

6.242 508

Manufacturer

Sartorius

Material membrane

Hydrosart®

Vivaflow 200, 30000 MWCO with pressure indicator

Manufacturer P/N

VF20P2

Part Number

9.049 796

Manufacturer

Sartorius

Material membrane

PES

Vivaflow 200, 3000 MWCO with pressure indicator

Manufacturer P/N

VF20P9

Part Number

6.282 579

Manufacturer

Sartorius

Material membrane

PES

Vivaflow 200, 2.000 MWCO Hydrosart
Available soon
Sartorius Vivaflow 200, 2.000 MWCO Hydrosart

NTD 32,761

Inc. VAT

Manufacturer P/N

VF20H9

Part Number

6.326 459

Manufacturer

Sartorius

Material membrane

Hydrosart®

More items to explore

Crossflow filter units Vivaflow 50R

ProductMaterial membraneMembrane surfaceMfr#Part#AvailabilityPrice
Hydrosart®50 cm²VF05H16.319 438NTD 20,769
Hydrosart®50 cm²VF05H06.490 315NTD 20,769
Hydrosart®50 cm²VF05H26.311 629NTD 20,769
Hydrosart®50 cm²VF05H44.666 017NTD 20,769

Frequently asked questions

It is a high-performance crossflow filtration system designed for efficient and reliable ultrafiltration. This system is ideal for laboratory applications requiring precise sample concentration and diafiltration. The integrated pressure indicator ensures optimal monitoring for enhanced process control.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 32,761

Inc. VAT