Representative Image

Reagecon Diagnostics Conductivity Standard 20 µS/cm at 25°C, 500 mL

Brand:Reagecon

Accuracy

Conductivity (25°C)

Package capacity

Content

Specifications

Compare models
Accuracy
±1 %
Accuracy
1 %
Conductivity (25°C)
20 µS/cm
No. of packages
1
Package capacity
500 ml
Container type
Bottle
Content
1 x Bottle of 500 ml
UNSPSC
41116166

NTD 7,983

Inc. VAT

Supplier Stock: 5
Delivery: 2-4 weeks

Product description

The Reagecon Diagnostics Conductivity Standard 20 µS/cm at 25°C, 500 mL, is a certified reference material designed for precise calibration of conductivity meters. Produced under ISO 17034 accreditation and NIST traceable, this aqueous-based, non-hazardous solution ensures accurate and reliable laboratory measurements. With a conductivity value of 20 µS/cm at 25°C and an accuracy of ±1%, it is ideal for quality control, method validation, and instrument qualification.

Key Features:

  • Brand: Reagecon Diagnostics
  • Conductivity Value: 20 µS/cm at 25°C
  • Volume: 500 mL
  • Accuracy: ±1%
  • Certification: NIST traceable, ISO 17034 accredited
  • Matrix: Aqueous-based, non-hazardous
  • Applications: Calibration of conductivity sensors, quality control, method validation, instrument qualification

This solution is essential for laboratories requiring precise and reliable conductivity measurements.

Compare similar models

Conductiivty Standard 20 Microsiemens/cm 25°, 500 ml

Manufacturer P/N

CSKC20

Part Number

6.802 901

Manufacturer

Reagecon

Accuracy

±1 %

Conductivity Standard 50 Microsiemens/cm 25°C, 500 ml

Manufacturer P/N

CSKC50

Part Number

6.074 754

Manufacturer

Reagecon

Accuracy

±1 %

Conductiivty solution 500ml, 5000 µS/cm

Manufacturer P/N

CSKC5M

Part Number

6.205 412

Manufacturer

Reagecon

Accuracy

±1 %

Conductivity solution 100 µS/cm 500 ml

Manufacturer P/N

CSKC100

Part Number

6.234 859

Manufacturer

Reagecon

Accuracy

±1 %

Conductiivty Standard 200 Microsiemens/cm 25°C, 500 ml

Manufacturer P/N

CSKC200

Part Number

6.802 902

Manufacturer

Reagecon

Accuracy

±1 %

Conductiivty Standard 10 Microsiemens/cm  25°C, 500 ml

Manufacturer P/N

CSKC10

Part Number

6.901 622

Manufacturer

Reagecon

Accuracy

±1 %

Conductiivty Standard 5 Microsiemens/cm 25°C, 500 ml

Manufacturer P/N

CSKC5

Part Number

6.901 629

Manufacturer

Reagecon

Accuracy

±1 %

Conductivity solution 84 µS/cm, 500 ml

Manufacturer P/N

CSKC84

Part Number

9.040 904

Manufacturer

Reagecon

Accuracy

±1 %

Conductivity solution 147 µS/cm, 500ml

Manufacturer P/N

CSKCS

Part Number

9.040 905

Manufacturer

Reagecon

Accuracy

±1 %

Conductiivty Standard 23.8 Microsiemens/cm 25°C, 500 ml

Manufacturer P/N

CSKC238

Part Number

6.259 883

Manufacturer

Reagecon

Accuracy

±1 %

Conductiivty Standard 1,000 M Microsiemens/cm 25°C, 500 ml

Manufacturer P/N

CSKC1000

Part Number

6.901 670

Manufacturer

Reagecon

Accuracy

±1 %

Conductivity solution 500ml, 100.000µS/cm
Available soon
Reagecon Conductivity Solution 500ml, 100.000 µS/cm

NTD 8,669

Inc. VAT

Manufacturer P/N

CSKC100M

Part Number

6.205 413

Manufacturer

Reagecon

Accuracy

±1 %

Conductivity solution 500ml, 500µS/cm

Manufacturer P/N

CSKC500

Part Number

6.205 415

Manufacturer

Reagecon

Accuracy

±1 %

Conductiivty Standard 50,000 Microsiemens/cm  25°C, 500 ml

Manufacturer P/N

CSKC50M

Part Number

6.210 129

Manufacturer

Reagecon

Accuracy

±1 %

Conductivity solution 1.3 µS/cm 250ml
Available soon
Reagecon Conductivity Solution 250ml, 1.3 µS/cm

NTD 8,669

Inc. VAT

Manufacturer P/N

CSKC13

Part Number

6.225 059

Manufacturer

Reagecon

Accuracy

±0.5 %

Conductivity solution 1413 µs/cm, 500ml

Manufacturer P/N

CSKCL

Part Number

9.040 906

Manufacturer

Reagecon

Accuracy

±1 %

Conductivity solution 12880 µS/cm 500ml
Available soon
Reagecon Conductivity Solution 12880 µS/cm, 500 mL

NTD 1,987

Inc. VAT

Manufacturer P/N

CSKC12880

Part Number

9.040 907

Manufacturer

Reagecon

Accuracy

±1 %

Conductivity standard 350000 µS/cm 500 ml (no dan. goods)

Manufacturer P/N

CSKC350M

Part Number

9.040 987

Manufacturer

Reagecon

Accuracy

±1 %

Conductivity standard 3000 µS/cm 500 ml
Available soon
Reagecon Conductivity Standard 3000 µS/cm, 500 ml

NTD 8,669

Inc. VAT

Manufacturer P/N

CSKC3M

Part Number

9.040 964

Manufacturer

Reagecon

Accuracy

±1 %

Conductiivty Standard 10,000 Microsiemens/cm 25°C, 500 ml

Manufacturer P/N

CSKC10M

Part Number

6.901 671

Manufacturer

Reagecon

Accuracy

±1 %

Frequently asked questions

It is a certified reference material designed for precise calibration of conductivity meters. Produced under ISO 17034 accreditation and NIST traceable, this aqueous-based, non-hazardous solution ensures accurate and reliable laboratory measurements. With a conductivity value of 20 µS/cm at 25°C and an accuracy of ±1%, it is ideal for quality control, method validation, and instrument qualification.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 7,983

Inc. VAT