Representative Image

PolyScience Water Bath 2 Ltr., Digital +5°C to 99°C, 240V, 50Hz

Capacity

Depth int.

Ext. dim. (WxDxH)

Ext. depth

Ext. height

Ext. width

Heating capacity

Height int.

Int. Dim. (WxDxH)

Int. width

Temperature

Type

With stopcock

Specifications

Compare models
Capacity
2 l
Depth int.
99 mm
Display
Digital
Ext. dim. (WxDxH)
305 x 229 x 267 mm
Ext. depth
229 mm
Ext. height
267 mm
Ext. width
305 mm
Power supply frequency
50 Hz
Heating capacity
120 W
Height int.
152 mm

NTD 33,953

Inc. VAT

Available soon

Product description

The PolyScience Water Bath 2 Ltr. Digital is engineered for precise temperature control in laboratory applications, with an operating range from +5°C to 99°C. Equipped with a digital interface and reliable heating system, this water bath ensures consistent and accurate temperature maintenance for your samples. It operates on 240V and 50Hz power supply, making it suitable for various lab settings. Featuring a color TFT display with control panel and advanced safety features, it is designed for ease of use and optimal performance.

Key Features:

  • Brand: PolyScience
  • Capacity: 2 liters
  • Temperature Range: +5°C to 99°C
  • Control: Digital temperature control for precision
  • Power Supply: 240V, 50Hz
  • Application: Ideal for laboratory sample heating and incubation
  • Display: Color TFT display with control panel
  • Calibration Function: Calibration offset feature
  • Temperature Control: Low liquid alarm and over temperature alarm
  • Operating Temperature: 5 user-programmable presets (temperature and duration)
  • 5 language options: English, German, French, Spanish, and Chinese
  • Timer: Integrated independent timer
  • Energy Efficiency: Eco-mode operation
  • Safety Thermostat: Safety thermostat
  • Lid Design: High-gabled, clear lids accommodate taller media bottles
  • Ease Of Use: Recessed handles for easy transport

Scope of Supply:

  • Digital water bath
  • Includes lid

This water bath is an essential instrument for labs requiring dependable and precise temperature control in sample processing and testing.

Downloads

Compare similar models

Water bath 2 Ltr., digital +5°C bis 99°C, 240V, 50/60Hz

Manufacturer P/N

WBE02A12E

Part Number

6.274 985

Manufacturer

PolyScience

Capacity

2 l

Water bath 28 Ltr., digital +5°C bis 99°C, 240V, 50/60Hz

Manufacturer P/N

WBE28A12E

Part Number

6.274 989

Manufacturer

PolyScience

Capacity

28 l

Water bath 10 Ltr., digital +5°C bis 99°C, 240V, 50/60Hz

Manufacturer P/N

WBE10A12E

Part Number

6.274 987

Manufacturer

PolyScience

Capacity

10 l

Water bath 5 Ltr., digital +5°C bis 99°C, 240V, 50/60Hz

Manufacturer P/N

WBE05A12E

Part Number

6.274 986

Manufacturer

PolyScience

Capacity

5 l

Water bath 20 Ltr., digital +5°C bis 99°C, 240V, 50/60Hz

Manufacturer P/N

WBE20A12E

Part Number

6.274 988

Manufacturer

PolyScience

Capacity

20 l

Frequently asked questions

It is engineered for precise temperature control in laboratory applications, with an operating range from +5°C to 99°C. Equipped with a digital interface and reliable heating system, this water bath ensures consistent and accurate temperature maintenance for your samples. It operates on 240V and 50Hz power supply, making it suitable for various lab settings. Featuring a color TFT display with control panel and advanced safety features, it is designed for ease of use and optimal performance.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 33,953

Inc. VAT