Representative Image

Mettler-Toledo Ion Selective Electrode (ISE) Bromide DX280

Material shaft

Max. temperature

Membrane

Temperature

Type

Specifications

Compare models
Connection plug
S7 plug head
Shaft length
120 mm
Material shaft
POM
Max. temperature
80 °C
Membrane
Solid state
Min. temperature
0 °C
Shaft Ø
12 mm
Temperature
0 ... 80 °C
Type
DX280-Br
UNSPSC
41115608

NTD 55,950

Inc. VAT

Available soon

Product description

The Mettler-Toledo Ion Selective Electrode (ISE) Bromide DX280 is a modular half-cell electrode designed for precise determination of bromide ion (Br⁻) concentrations in aqueous solutions. Featuring a solid-state membrane and S7 plug head, this electrode offers a wide measuring range and is ideal for applications requiring accurate bromide analysis.

Key Features:

  • Brand: Mettler-Toledo
  • Type: Ion Selective Electrode for bromide (Br⁻)
  • Model: DX280
  • Measuring Range: 1 × 10⁻⁶ to 1 mol/L
  • pH Range: 2 to 13
  • Temperature Range: 0°C to 80°C
  • Membrane Material: Solid state
  • Shaft Material: Polyoxymethylene (POM)
  • Connector: S7 plug head
  • Application: Suitable for environmental monitoring, water testing, and laboratory analysis

Ensure reliable and accurate bromide measurements with this durable and versatile electrode.

Downloads

Compare similar models

Ion-selective electrodes (ISE), bromide, DX280

Manufacturer P/N

51340300

Part Number

9.041 721

Manufacturer

Mettler-Toledo

Material shaft

POM

Ion-selective electrodes,Chloride

Manufacturer P/N

51340400

Part Number

9.041 723

Manufacturer

Mettler-Toledo

Material shaft

POM

Ion-selective electrodes,Fluoride DX219-F

Manufacturer P/N

51340500

Part Number

9.041 725

Manufacturer

Mettler-Toledo

Material shaft

POM

Ion-selective electrodes (ISE) sodium, DX223

Manufacturer P/N

51340263

Part Number

9.041 735

Manufacturer

Mettler-Toledo

Material shaft

Glass

Ion-selective electrodes,Ammonium
Available soon
Mettler-Toledo Ion-Selective Electrodes, Ammonium

NTD 55,950

Inc. VAT

Manufacturer P/N

51340900

Part Number

9.041 733

Manufacturer

Mettler-Toledo

Material shaft

-

Ion-selective electrodes (ISE) copper DX264-Cu

Manufacturer P/N

51107678

Part Number

9.041 736

Manufacturer

Mettler-Toledo

Material shaft

POM

Ion selective electrodes (ISE) calcium DX 240

Manufacturer P/N

51340600

Part Number

9.041 730

Manufacturer

Mettler-Toledo

Material shaft

-

Ion-selective electrodes,Nitrate

Manufacturer P/N

51340800

Part Number

9.041 732

Manufacturer

Mettler-Toledo

Material shaft

-

Gas sensitive electrode (GSE) ammonia

Manufacturer P/N

51341000

Part Number

9.041 745

Manufacturer

Mettler-Toledo

Material shaft

PPS

Ion-selective electrodes (ISE) potassium, DX239

Manufacturer P/N

51340700

Part Number

9.041 731

Manufacturer

Mettler-Toledo

Material shaft

-

Frequently asked questions

It is a modular half-cell electrode designed for precise determination of bromide ion (Br⁻) concentrations in aqueous solutions. Featuring a solid-state membrane and S7 plug head, this electrode offers a wide measuring range and is ideal for applications requiring accurate bromide analysis.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 55,950

Inc. VAT