Representative Image

Ludwig Schneider Pt100 Transition-Sleeve Sensor with Handle – Class A, −90 °C to +350 °C, 400 mm, Ø 3 mm, 3 m Cable

Cable length

Ø

Dimensions (ØxL)

Length

Max. temperature

Min. temperature

Temperature

Specifications

Compare models
Accuracy class
A
Cable length
3 m
Ø
3 mm
Dimensions (ØxL)
3 x 400 mm
Length
400 mm
Material
Stainless steel
Max. temperature
350 °C
Min. temperature
-90 °C
Resolution
0.01 °C
Temperature
-90 ... 350 °C

NTD 12,317

Inc. VAT

Available soon

Product description

The Ludwig Schneider Pt100 Transition‑Sleeve Sensor with Handle provides high-precision temperature monitoring for demanding laboratory and industrial applications. Equipped with a Class A Pt100 element, it ensures reliable performance across a range of −90 °C to +350 °C. The probe is a robust stainless steel shaft, Ø 3 mm in diameter and 400 mm in length, designed for easy thermowell integration via its transition-sleeve design. A 3 metre cable and ergonomic handle add flexibility and safety during use and connection.

Key Features:

  • Brand: Ludwig Schneider
  • Sensor Type: Pt100 (Platinum Resistance Thermometer), Class A accuracy
  • Temperature Range: −90 °C to +350 °C
  • Probe Dimensions: Ø 3 mm × 400 mm
  • Cable Length: 3 m
  • Design: Transition-sleeve with ergonomic handle—ideal for thermowell use
  • Applications: Calibration labs, process control, industrial temperature logging

Blending precision, durability, and ergonomic design, this sensor is crafted for professionals needing dependable, accessible temperature sensing in critical environments.

Downloads

Compare similar models

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 400mm,

Manufacturer P/N

70140

Part Number

6.273 650

Manufacturer

Ludwig Schneider

Cable length

3 m

Pt100 transition sleeve with handle Class A, application range -50 to+200 ° C Nominal length 150mm,

Manufacturer P/N

70128

Part Number

6.273 647

Manufacturer

Ludwig Schneider

Cable length

3 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 400mm,

Manufacturer P/N

70130

Part Number

6.273 449

Manufacturer

Ludwig Schneider

Cable length

2 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 300mm,

Manufacturer P/N

70137

Part Number

6.273 648

Manufacturer

Ludwig Schneider

Cable length

3 m

Pt100 transition sleeve with handle Class A, application range -50 to+200 ° C Nominal length 150mm,

Manufacturer P/N

70133

Part Number

6.273 444

Manufacturer

Ludwig Schneider

Cable length

2 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 400mm,

Manufacturer P/N

70132

Part Number

6.273 672

Manufacturer

Ludwig Schneider

Cable length

5 m

Pt100 transition sleeve with handle Class A, application range -50 to+200 ° C Nominal length 150mm,

Manufacturer P/N

70135

Part Number

6.273 667

Manufacturer

Ludwig Schneider

Cable length

5 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 300mm,

Manufacturer P/N

70126

Part Number

6.273 670

Manufacturer

Ludwig Schneider

Cable length

5 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 300mm,

Manufacturer P/N

70113

Part Number

6.273 649

Manufacturer

Ludwig Schneider

Cable length

3 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 400mm,

Manufacturer P/N

70131

Part Number

6.273 651

Manufacturer

Ludwig Schneider

Cable length

3 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 400mm,

Manufacturer P/N

70139

Part Number

6.273 448

Manufacturer

Ludwig Schneider

Cable length

2 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 300mm,

Manufacturer P/N

70112

Part Number

6.273 447

Manufacturer

Ludwig Schneider

Cable length

2 m

Pt100 transition sleeve with handle Class A, application range -50 to+200 ° C Nominal length 150mm,

Manufacturer P/N

70129

Part Number

6.273 668

Manufacturer

Ludwig Schneider

Cable length

5 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 300mm,

Manufacturer P/N

70138

Part Number

6.273 669

Manufacturer

Ludwig Schneider

Cable length

5 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 400mm,

Manufacturer P/N

70141

Part Number

6.273 671

Manufacturer

Ludwig Schneider

Cable length

5 m

Pt100 transition sleeve with handle Class A, application range -50 to+200 ° C Nominal length 150mm,

Manufacturer P/N

70134

Part Number

6.273 646

Manufacturer

Ludwig Schneider

Cable length

3 m

Pt100 transition sleeve with handle Class A, application range -90 to+350 ° C Nominal length 300mm,

Manufacturer P/N

70136

Part Number

6.273 446

Manufacturer

Ludwig Schneider

Cable length

2 m

Pt100 transition sleeve with handle Class A, application range -50 to+200 ° C Nominal length 150mm,

Manufacturer P/N

70127

Part Number

6.273 445

Manufacturer

Ludwig Schneider

Cable length

2 m

Frequently asked questions

It provides high-precision temperature monitoring for demanding laboratory and industrial applications. Equipped with a Class A Pt100 element, it ensures reliable performance across a range of −90 °C to +350 °C. The probe is a robust stainless steel shaft, Ø 3 mm in diameter and 400 mm in length, designed for easy thermowell integration via its transition-sleeve design. A 3 metre cable and ergonomic handle add flexibility and safety during use and connection.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 12,317

Inc. VAT