Representative Image

Ludwig Schneider Precision Laboratory Thermometer -10...+50°C, 0.1°C Graduation, Embedded Form, Total Immersion Depth, Non-Calibratable

Division

Length

Max. temperature

Min. temperature

Temperature

Specifications

Compare models
Capillary
Uncoated, prismatic
Colour filling
Red
Division
0.1 °C
Length
420 mm
Max. Ø
9 mm
Max. temperature
50 °C
Min. temperature
-10 °C
Shape thermometer
Enclosed scale
Temperature
-10 ... 50 °C
UNSPSC
41112239

NTD 5,093

Inc. VAT

Available soon

Product description

The Ludwig Schneider Precision Laboratory Thermometer offers high-accuracy temperature measurements ranging from -10°C to +50°C with a 0.1°C graduation. Designed in an embedded form with a total immersion depth, this thermometer is ideal for precise laboratory applications where calibration is not required.

Key Features:

  • Brand: Ludwig Schneider
  • Measuring Range: -10°C to +50°C
  • Graduation: 0.1°C
  • Immersion Depth: Total
  • Form: Embedded
  • Calibration: Not calibratable
  • Capillary: Colourless prismatic
  • Filling: Environmentally friendly red liquid
  • Diameter: Ø9 mm ±1 mm
  • Length: 420 mm
  • Part Number: 1042349
  • HS Code: 90251180

This thermometer is a reliable choice for laboratories requiring precise temperature measurements without the need for calibration.

Compare similar models

Precision laboratory thermometer -10...+50°C:0,1°C, embedded form, immersion depth total, not calibratable

Manufacturer P/N

1042349

Part Number

6.266 842

Manufacturer

Ludwig Schneider

Division

0.1 °C

Precision-Laboratory thermometer -10...+50°C:0.5°C embedded shape, immersion depth:total, red filling, length 220mm

Manufacturer P/N

1042343

Part Number

6.284 649

Manufacturer

Ludwig Schneider

Division

0.5 °C

Precision laboratory thermometer 0...50°C:0,1°C, embedded form, immersion depth total, not calibratable

Manufacturer P/N

1042348

Part Number

6.262 008

Manufacturer

Ludwig Schneider

Division

0.1 °C

Precision laboratory thermometer -10...+200°C:1°C, embedded form, immersion depth total, red filling,

Manufacturer P/N

1042350

Part Number

6.266 291

Manufacturer

Ludwig Schneider

Division

1 °C

Precision laboratory thermometer -10...+30°C:0,1°C embedded shape, immerison depth: total, red filling, length 300mm

Manufacturer P/N

1042353

Part Number

7.971 169

Manufacturer

Ludwig Schneider

Division

0.1 °C

Precision-Laboratory thermometer -5...+50°C:0,2°C embedded shape, immersion depth:total, red filling, length 350mm

Manufacturer P/N

1042346

Part Number

7.971 170

Manufacturer

Ludwig Schneider

Division

0.2 °C

Percision-laboratory thermometer-10+100°C in 0,5°C enclosed, ACCU-SAFE, red filling, lenght:270mm

Manufacturer P/N

1042344

Part Number

7.971 874

Manufacturer

Ludwig Schneider

Division

0.5 °C

Precision Laboratory Thermometer-10+200°C in 0,5°C enclosed, red filling, length 450mm

Manufacturer P/N

1042351

Part Number

7.971 873

Manufacturer

Ludwig Schneider

Division

0.5 °C

Precision thermometer -5...+100°C in 0.2°C enclosed form, capillary: colourless prismatic, red filling, immersion: total, length: 420 mm,

Manufacturer P/N

1042347

Part Number

6.521 678

Manufacturer

Ludwig Schneider

Division

0.2 °C

Frequently asked questions

It offers high-accuracy temperature measurements ranging from -10°C to +50°C with a 0.1°C graduation. Designed in an embedded form with a total immersion depth, this thermometer is ideal for precise laboratory applications where calibration is not required.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 5,093

Inc. VAT