Representative Image

Kern & Sohn Analytical Balance ABP 100-5AM, Weighing Capacity 135 g, Readability 0.00001 g

Linearity

Max. load

Readability

Reproducibility

Type

Specifications

Compare models
Adjusting program
Internal
Depth
370 mm
Depth weighing plate
91 mm
Dimensions (WxDxH)
220 x 370 x 350 mm
Power supply frequency
50 Hz
Height
350 mm
Linearity
±0,1 mg
Max. load
135 g
Max. voltage
240 V·AC
Min. voltage
220 V

NTD 346,644

Inc. VAT

Available soon

Product description

The Kern & Sohn Analytical Balance ABP 100-5AM, Weighing Capacity 135 g, Readability 0.00001 g is designed for high-precision weighing in laboratory environments. With three automatic sliding doors that can be opened and closed using sensors, an integrated ioniser and single-cell generation, this balance supports fast, stable and repeatable weighing results.

Key Features:

  • Brand: Kern & Sohn
  • Model: ABP 100-5AM
  • Balance Type: Analytical balance
  • Weighing Capacity: 135 g
  • Readability: 0.00001 g
  • Doors: Three automatic sliding doors with sensor operation and memory function
  • Display: OLED display
  • Ioniser: Integrated ioniser
  • Draft Shield: Adjustable internal draft shield
  • Weighing Plate: Multifunctional weighing plate for samples, sample paper, PCR tubes and microcentrifuge tubes
  • Adjustment: Automatic internal adjustment with temperature change ≥ 1 °C or time-controlled every 4 h
  • Functions: Minimum weight warning, dosage aid, recipe weighing and combined tare/print function
  • Interfaces: USB data interfaces and RS-232
  • Scope of Supply: Analytical balance, protective working cover and universal mains adapter

This analytical balance is a practical choice for laboratories requiring precise, stable and repeatable weighing performance with automatic door operation and advanced sample handling features.

Compare similar models

Analytical Balance ABP 100-5AM Weighing capacity (max.) 135 g Readability (d): 0.00001 g

Manufacturer P/N

ABP 100-5AM

Part Number

6.325 002

Manufacturer

KERN & SOHN

Linearity

±0,1 mg

Analytical Balance ABP 300-4AM Weighing capacity (max.) 320 g Readability (d):  0,0001 g

Manufacturer P/N

ABP 300-4AM

Part Number

4.690 324

Manufacturer

KERN & SOHN

Linearity

±0,3 mg

Analytical Balance ABP 200-5DAM Weighing capacity (max.) 102 g; 220 g Readability (d):  0,00001 g; 0,0001 g

Manufacturer P/N

ABP 200-5DAM

Part Number

4.690 323

Manufacturer

KERN & SOHN

Linearity

±0,1/0,2 mg

Analytical Balance ABP 200-5AM Weighing capacity (max.) 220 g Readability (d):  0,00001 g

Manufacturer P/N

ABP 200-5AM

Part Number

4.690 322

Manufacturer

KERN & SOHN

Linearity

±0,1 mg

Analytical Balance ABP 100-5DAM Weighing capacity (max.) 52 g; 120 g Readability (d):  0,00001 g; 0,0001 g

Manufacturer P/N

ABP 100-5DAM

Part Number

4.690 321

Manufacturer

KERN & SOHN

Linearity

±0,05/0,2 mg

Analytical Balance ABP 200-4AM Weighing capacity (max.) 220 g Readability (d): 0.0001 g

Manufacturer P/N

ABP 200-4AM

Part Number

6.325 003

Manufacturer

KERN & SOHN

Linearity

±0,2 mg

Frequently asked questions

It is designed for high-precision weighing in laboratory environments. With three automatic sliding doors that can be opened and closed using sensors, an integrated ioniser and single-cell generation, this balance supports fast, stable and repeatable weighing results.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 346,644

Inc. VAT