Representative Image

Julabo Dynamic Temperature Control System PRESTO A70, with Natural Refrigerant

Brand:JULABO

Refrigerant

Type

Specifications

Compare models
Cooling capacity at 20 °C
1,12 kW
Ext. dim. (WxDxH)
570 x 640 x 880 mm
Ext. depth
640 mm
Ext. height
880 mm
Ext. width
570 mm
Heating capacity
1.8 kW
IP code
IP 20
Max. delivery pressure
1.7 bar
Max. temperature
250 °C
Min. temperature
-75 °C

NTD 1,431,147

Inc. VAT

Available soon

Product description

The Julabo Dynamic Temperature Control System PRESTO A70, with Natural Refrigerant offers advanced temperature control for a variety of laboratory applications. It uses a natural refrigerant to provide an environmentally friendly solution, ensuring optimal performance and efficiency. Ideal for precise temperature management in research and industrial settings, this system guarantees reliability and long-lasting durability.

Key Features:

  • Brand: Julabo
  • Refrigerant: Uses natural refrigerant for environmentally conscious operation
  • Application: Designed for dynamic temperature control in laboratories and industrial applications
  • Performance: High efficiency and precision for optimal results
  • Packaging: Sold as a complete system

The Julabo PRESTO A70 is a cutting-edge solution for precise and sustainable temperature management in demanding scientific and industrial environments.

Downloads

Accessories

Temperature hoses for highly dynamic temperature control systems PRESTO™, stainless steel 1.4404, triple insulation

ProductTemperature resistanceMaterialMfr#Part#AvailabilityPrice
-100 ... 350 °CStainless steel 1.440489302626.270 832NTD 36,987
-100 ... 350 °CStainless steel 1.440489302847.984 537NTD 94,165
-100 ... 350 °CStainless steel 1.440489302734.684 005NTD 63,029
-100 ... 350 °CStainless steel 1.440489302636.286 679NTD 43,850
-100 ... 350 °CStainless steel 1.440489302616.260 774NTD 33,772
-100 ... 350 °CStainless steel 1.440489302646.324 558NTD 57,900
-100 ... 350 °CStainless steel 1.440489302744.701 561NTD 77,405
-100 ... 350 °CStainless steel 1.440489302716.326 887NTD 44,139
-100 ... 350 °CStainless steel 1.440489302834.701 563NTD 76,322
-100 ... 350 °CStainless steel 1.440489302854.688 328NTD 143,433
-100 ... 350 °CStainless steel 1.440489302724.701 560NTD 54,433
-100 ... 350 °CStainless steel 1.440489302824.688 329NTD 63,029
-100 ... 350 °CStainless steel 1.440489302754.701 562NTD 120,677

ProfiNet Interface

ProductDescriptionUNSPSCMfr#Part#AvailabilityPrice
ProfiNet Interface4110371589000264.686 939NTD 79,283

Compare similar models

Dynamic temperature control system PRESTO A70 with natural refrigerant

Manufacturer P/N

9420701.N1

Part Number

4.686 943

Manufacturer

JULABO

Refrigerant

R449A

PRESTO A70 Highly dynamic temp. control system Stage 1 + 2 with natural refrigerant *please remain transportation regulations*

Manufacturer P/N

9420701.N2

Part Number

4.721 596

Manufacturer

JULABO

Refrigerant

R290

More items to explore

Highly dynamic temperature control systems PRESTO™, air-cooled 1-stage

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
A 30Mains connection94203009.857 915NTD 692,493
A 41Mains connection9420411.N14.686 942NTD 1,001,283
A 38Mains connection9420381.N14.686 941NTD 972,423

Highly dynamic temperature control systems PRESTO™, water-cooled 1-stage

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
W 41Mains connection9421411.N14.686 944NTD 1,038,811

Frequently asked questions

It offers advanced temperature control for a variety of laboratory applications. It uses a natural refrigerant to provide an environmentally friendly solution, ensuring optimal performance and efficiency. Ideal for precise temperature management in research and industrial settings, this system guarantees reliability and long-lasting durability.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 1,431,147

Inc. VAT