Representative Image

HILGENBERG NMR Tubes 0.15 mm for Bruker Match System, OD 1.0±0.010 mm, ID 0.7±0.010 mm, Length 100 mm, One End Closed, Pack of 10

Ext. Ø

Int. Ø

Tolerance ext. Ø

Tolerance int. Ø

Wall thickness

Specifications

Compare models
Ext. Ø
1.0 mm ± 0.010
Ext. Ø
1.0 mm
Int. Ø
0.7 mm ± 0.010
Int. Ø
0.7 mm
Length
100 mm
Tolerance ext. Ø
0.010 mm
Tolerance int. Ø
0.010 mm
UNSPSC
41115700
Wall thickness
0,15 mm

NTD 2,203

Inc. VAT

Available soon

Product description

The HILGENBERG NMR Tubes 0.15 mm are designed for use with the Bruker Match system, offering precision and reliability for NMR spectroscopy. With an outer diameter (OD) of 1.0±0.010 mm and an inner diameter (ID) of 0.7±0.010 mm, these tubes ensure accurate and consistent results. The 100 mm length and one closed end provide ideal conditions for high-quality NMR analysis. Supplied in a pack of 10, these tubes are perfect for laboratories requiring dependable and precise sample containment.

Key Features:

  • Brand: HILGENBERG
  • Outer Diameter (OD): 1.0±0.010 mm
  • Inner Diameter (ID): 0.7±0.010 mm
  • Length: 100 mm
  • End Type: One end closed
  • Pack Size: Pack of 10
  • Compatibility: Ideal for use with Bruker Match system

The HILGENBERG NMR Tubes provide precise dimensions and high-quality construction, making them an excellent choice for NMR experiments in professional laboratories.

Compare similar models

NMR tubes 0.15mm,for Bruker Match system OD 1.0±0.010mm, ID 0.7±0.010, length 100mm, one end closed, pack of 10

Manufacturer P/N

2001727

Part Number

6.281 691

Manufacturer

Hilgenberg

Ext. Ø

1.0 mm ± 0.010

NMR tubes 0.30mm,for Bruker Match system OD 3.0±0.025mm, ID 2.4±0.025, length 100mm, one end closed, pack of 10

Manufacturer P/N

2001724

Part Number

7.673 680

Manufacturer

Hilgenberg

Ext. Ø

3.0 mm ± 0.025

NMR tubes 0.20mm,for Bruker Match system OD 2.0±0.010mm, ID 1.6±0.010, length 100mm, one end closed, pack of 10

Manufacturer P/N

2001711

Part Number

6.281 692

Manufacturer

Hilgenberg

Ext. Ø

2.0 mm ± 0.010

NMR tubes 0.40mm,for Bruker Match system OD 4.25±0.03mm, ID 3.45±0.03, length 100mm, one end closed, pack of 10

Manufacturer P/N

2001734

Part Number

6.281 693

Manufacturer

Hilgenberg

Ext. Ø

4.25 mm ± 0.03

NMR tubes 0.20mm,for Bruker Match system OD 1.7±0.010mm, ID 1.3±0.010, length 100mm, one end closed, pack of 10

Manufacturer P/N

2001710

Part Number

7.673 679

Manufacturer

Hilgenberg

Ext. Ø

1.7 mm ± 0.010

NMR tubes 0.20mm,for Bruker Match system OD 2.5±0.010mm, ID 2.1±0.010, length 100mm, one end closed, pack of 10

Manufacturer P/N

2001712

Part Number

7.673 678

Manufacturer

Hilgenberg

Ext. Ø

2.5 mm ± 0.010

NMR tubes 0.40mm,for Bruker Match system OD 5.0±0.025mm, ID 4.20±0.025, length 100mm, one end closed, pack of 10

Manufacturer P/N

2001726

Part Number

6.281 694

Manufacturer

Hilgenberg

Ext. Ø

5.0 mm ± 0.025

NMR tubes 0.35mm,for Bruker Match system OD 4.0±0.025mm, ID 3.3±0.025, length 100mm, one end closed, pack of 10

Manufacturer P/N

2001725

Part Number

7.673 677

Manufacturer

Hilgenberg

Ext. Ø

4.0 mm ± 0.025

Frequently asked questions

It are designed for use with the Bruker Match system, offering precision and reliability for NMR spectroscopy. With an outer diameter (OD) of 1.0±0.010 mm and an inner diameter (ID) of 0.7±0.010 mm, these tubes ensure accurate and consistent results. The 100 mm length and one closed end provide ideal conditions for high-quality NMR analysis. Supplied in a pack of 10, these tubes are perfect for laboratories requiring dependable and precise sample containment.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 2,203

Inc. VAT

MoQ (10)x(10)