Representative Image

Eppendorf CryoCube F570h 230V/50Hz, CH

Brand:Eppendorf

Plug type

Specifications

Compare models
Depth int.
575 mm
Energy consumption (24h)
7.4 kWh
Ext. dim. (WxDxH)
1,103 x 898 x 1,950 mm
Ext. depth
898 mm
Ext. height
1950 mm
Ext. width
1103 mm
Power supply frequency
50 Hz
Height int.
1265 mm
Int. Dim. (WxDxH)
765 x 575 x 1,265 mm
Int. width
765 mm

NTD 691,770

Inc. VAT

Available soon

Product description

The Eppendorf CryoCube F570h 230 V/50 Hz, CH Plug is an ultra-low temperature freezer from Eppendorf designed for long-term storage of temperature-sensitive laboratory samples. Ultra-low temperature freezer with a two-stage cascade cooling system for reliable cooling processes. Its documented configuration includes electrical supply: 230 V, 50 Hz, door handle: Ergonomic door handle requires less force and makes handling easier, and venting: Automatic vent port for quick access to samples.

Key Features:

  • Brand: Eppendorf
  • Model: CryoCube F570h
  • Product Type: Ultra-Low Temperature Freezer
  • Electrical Supply: 230 V, 50 Hz
  • Door Handle: Ergonomic door handle requires less force and makes handling easier
  • Venting: Automatic vent port for quick access to samples
  • Inner Doors: Five insulated, detachable inner doors
  • Access Ports: Two access ports in the upper corner for external probes or backups
  • Power Switch Security: Lockable security plate protects the power switch
  • Filter Access: Easy access to filter
  • Interior: Stainless steel interior for easy cleaning
  • Exterior: Powder-coated steel exterior
  • Refrigerant: Environmentally friendly hydrocarbon-based refrigerants (R290/R170)
  • Cooling System: Ultra-low temperature freezer with a two-stage cascade cooling system for reliable cooling processes
  • Application: Ideal for the long-term storage of samples

The Eppendorf CryoCube F570h 230 V/50 Hz, CH Plug supports long-term storage of temperature-sensitive laboratory samples where the stated configuration is required. Confirm electrical supply, included accessories, and installation requirements before ordering.

Accessories

Racks for ultra-low temperature freezers CryoCube® F440/F570/F740 (5-compartment models), stainless steel

ProductType of rackMaterialMfr#Part#AvailabilityPrice
CompartmentsStainless steel60010214104.720 599NTD 8,922
CompartmentsStainless steel60010219104.720 600NTD 9,463
CompartmentsStainless steel60010213104.720 598NTD 8,849
CompartmentsStainless steel60010212104.720 597NTD 9,572

DWP rack for ultra-low temperature freezers CryoCube® F440/F570/F740 (5-compartment models), stainless steel

ProductType of rackMaterialMfr#Part#AvailabilityPrice
CompartmentsStainless steel60010211104.720 596NTD 12,859

Compare similar models

CryoCube F570h 230V/50Hz, CH
Available soon
Eppendorf CryoCube F570h 230V/50Hz, CH

NTD 691,770

Inc. VAT

Manufacturer P/N

F571340037

Part Number

4.721 228

Manufacturer

Eppendorf

Plug type

CH

CryoCube F570h, 230V/50Hz, EU/UK
Available soon
Eppendorf CryoCube F570h, 230V/50Hz, EU/UK

NTD 691,770

Inc. VAT

Manufacturer P/N

F571340031

Part Number

4.720 698

Manufacturer

Eppendorf

Plug type

EU/UK

Frequently asked questions

It is an ultra-low temperature freezer from Eppendorf designed for long-term storage of temperature-sensitive laboratory samples. Ultra-low temperature freezer with a two-stage cascade cooling system for reliable cooling processes.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story