Representative Image

BRAND Dispensette S Digital, 1-10 mL, with Recirculation Valve

Brand:BRAND

Accuracy

Division

Dosing volume

Max. dosing volume

Min. dosing volume

Precision

With recirculation valve

Specifications

Compare models
HS Code #
84131900
Accuracy
0.5 ± R%
Division
0.05 ml
Dosing volume
1 ... 10 ml
Length suction tube
330 mm
Max. dosing volume
10 ml
Min. dosing volume
1 ml
Precision
0.1 ≤·VK%
Thread
GL 45
UNSPSC
41121516
With recirculation valve
Yes

NTD 28,137

Inc. VAT

Supplier Stock: 5
Delivery: 2-4 weeks

Product description

The BRAND Dispensette S Digital, 1-10 mL, with Recirculation Valve is a precise and reliable dispensing solution for laboratories. Designed for accurate liquid handling, this dispenser features a recirculation valve, ensuring efficient and consistent dispensing without waste. Ideal for applications requiring precision, it offers seamless control and reduces the risk of contamination, making it essential for high-precision laboratory environments.

Key Features:

  • Brand: BRAND
  • Volume Range: 1-10 mL for flexible dispensing
  • Recirculation Valve: Reduces waste and ensures accurate dispensing
  • Precision: Ideal for applications requiring high accuracy
  • Application: Suitable for laboratory liquid handling and dispensing

This dispenser is a vital tool for laboratories in need of high-precision liquid handling with enhanced control and minimal waste.

Accessories

Bottle-thread adapters, PP and ETFE

ProductMaterialThread ext.Mfr#Part#AvailabilityPrice
PPGL327043259.284 625NTD 650
ETFEGL457043987.020 224NTD 1,950
ETFEGL327043789.284 678NTD 1,445
ETFEGL327043909.284 690NTD 1,878
PTFEGL457043917.079 312NTD 2,167
PPGL457043487.020 221NTD 2,781
ETFEGL327043889.284 688NTD 1,734
PPGL327043459.284 645NTD 1,011
PPGL327043389.284 638NTD 939
ETFEGL327043759.284 675NTD 1,445
PPGL327043409.284 640NTD 975
ETFEGL457043997.020 225NTD 1,987
PPGL327043229.284 622NTD 686
ETFEGL327043959.284 695NTD 2,203
PPGL457043504.668 894NTD 2,384

Telescopic filling tubes, FEP

ProductDescriptionForMfr#Part#AvailabilityPrice
125 ... 240 mmDispensette ® S/S Organic/S Trace Analysis/seripettor ® pro/Dispensette ® III/TA7082126.270 816In stockNTD 1,553
70 ... 140 mmDispensette ® S/S Organic/S Trace Analysis/seripettor ® pro/Dispensette ® III/TA7082106.270 815NTD 1,084
195 ... 350 mmDispensette ® S/S Organic/S Trace Analysis/seripettor ® pro/Dispensette ® III/TA7082146.283 744NTD 2,167
250 ... 480 mmDispensette ® S/S Organic/S Trace Analysis/seripettor ® pro/Dispensette ® III/TA7082166.270 817NTD 1,698
170 ... 330 mmDispensette ® S/S Organic/S Trace Analysis/seripettor ® pro/Dispensette ® III/TA/Titrette®7082186.270 818NTD 2,167
250 ... 480 mmDispensette ® S/S Organic/S Trace Analysis/seripettor ® pro/Dispensette ® III/TA/Titrette®7082206.270 819NTD 2,276

Compare similar models

Dispensette® S Digital 1 - 10 ml, with recirculation valve

Manufacturer P/N

4600341

Part Number

9.284 416

Manufacturer

BRAND

Accuracy

0.5 ± R%

Dispensette® S Digital 1 - 10 ml, without recirculation valve

Manufacturer P/N

4600340

Part Number

9.284 413

Manufacturer

BRAND

Accuracy

0.5 ± R%

Dispensette® S Digital 2,5 - 25 ml, with recirculation valve

Manufacturer P/N

4600351

Part Number

9.284 419

Manufacturer

BRAND

Accuracy

0.5 ± R%

Dispensette® S Digital 5 - 50 ml, without recirculation valve

Manufacturer P/N

4600360

Part Number

9.284 422

Manufacturer

BRAND

Accuracy

0.5 ± R%

Dispensette® S Digital 5 - 50 ml, with recirculation valve

Manufacturer P/N

4600361

Part Number

9.284 423

Manufacturer

BRAND

Accuracy

0.5 ± R%

Dispensette® S Digital 0,5 - 5 ml, without recirculation valve

Manufacturer P/N

4600330

Part Number

9.284 409

Manufacturer

BRAND

Accuracy

0.5 ± R%

Dispensette® S Digital 2,5 - 25 ml, without recirculation valve

Manufacturer P/N

4600350

Part Number

9.284 417

Manufacturer

BRAND

Accuracy

0.5 ± R%

Dispensette® S Digital 0,1 - 1 ml, with recirculation valve

Manufacturer P/N

4600311

Part Number

9.284 383

Manufacturer

BRAND

Accuracy

0.6 ± R%

Dispensette® S Digital 0,1 - 1 ml, without recirculation valve

Manufacturer P/N

4600310

Part Number

9.284 382

Manufacturer

BRAND

Accuracy

0.6 ± R%

Dispensette® S Digital 0,2 - 2 ml, with recirculation valve

Manufacturer P/N

4600321

Part Number

9.284 408

Manufacturer

BRAND

Accuracy

0.5 ± R%

Dispensette® S Digital 0,2 - 2 ml, without recirculation valve

Manufacturer P/N

4600320

Part Number

9.284 407

Manufacturer

BRAND

Accuracy

0.5 ± R%

Dispensette® S Digital 0,5 - 5 ml, with recirculation valve

Manufacturer P/N

4600331

Part Number

9.284 412

Manufacturer

BRAND

Accuracy

0.5 ± R%

Frequently asked questions

It is a precise and reliable dispensing solution for laboratories. Designed for accurate liquid handling, this dispenser features a recirculation valve, ensuring efficient and consistent dispensing without waste. Ideal for applications requiring precision, it offers seamless control and reduces the risk of contamination, making it essential for high-precision laboratory environments.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story