Representative Image

Bohlender b.safe Waste Cap S65 4x UNF1/4", 1x GL14, 1x NPT1/8"

Brand:Bohlender

Capillary connections

No. of blind plugs

No. of fittings

No. of olives

Specifications

Compare models
HS Code #
39235090
Capillary connections
4
Connection for exhaust filter
1
Hose connections
1
Material
PE
No. of blind plugs
3
No. of fittings
4 x 1,6/ 2,2/ 3,2 mm
No. of olives
1
Thread
S 65
UNSPSC
41115700

NTD 7,657

Inc. VAT

Available soon

Product description

The Bohlender b.safe Waste Cap S65 is designed for laboratory applications, providing secure connections and high-quality performance. Made of durable polyethylene (PE), it features a freely movable PTFE insert and four UNF 1/4"" fittings, one GL14 connection for an exhaust filter (sold separately), and one NPT 1/8"" hose connection. This versatile waste cap ensures proper sealing and safety for handling various laboratory fluids, and supports connecting capillaries (O.D. 1.6/2.2/3.2 mm) and hose olives for tubing with inner diameters of 5.5 to 8 mm.

Key Features:

  • Brand: Bohlender
  • Material: Durable polyethylene (PE)
  • Thread and Insert: S65 with freely movable PTFE insert
  • Connections: 4x UNF 1/4"", 1x GL14, 1x NPT 1/8""
  • Application: Ideal for waste management and fluid handling in laboratories
  • Packaging: Sold individually

Scope of Supply:

  • Fittings (UNF 1/4“)
  • Blind fittings (UNF 1/4“)
  • Hose olive (NPT 1/8")

This b.safe Waste Cap ensures safety and reliability for laboratory environments handling various waste and fluid types.

Accessories

Exhaust Filter, PP

ProductMaterialFilter sizeMfr#Part#AvailabilityPrice
PPSM 506-016.313 839In stockNTD 5,743
PPMM 506-026.313 840In stockNTD 8,344
PPLM 506-036.313 841In stockNTD 10,692

Hose connectors for Waste Caps

ProductMaterialLengthMfr#Part#AvailabilityPrice
PP45 mmM 503-014.681 618NTD 867
PTFE45 mmM 503-054.681 619NTD 1,698
PP30 mmM 503-084.681 620NTD 831
PP32 mmM 503-094.681 621NTD 722
PP23 mmM 503-104.681 622NTD 722
PP26 mmM 503-114.681 623NTD 722
PP26 mmM 503-124.681 624NTD 722
PP30 mmM 503-134.681 625NTD 722
PP36 mmM 503-144.681 626NTD 722
PTFE45 mmM 503-154.681 627NTD 1,770
PP40 mmM 503-164.681 628NTD 722
PP48 mmM 513-014.681 643NTD 722
PP41 mmM 513-024.681 644NTD 722
PP30 mmM 518-014.681 647NTD 795

Compare similar models

b.safe Waste Cap S65 4x UNF1/4", 1x GL14, 1x NPT1/8"

Manufacturer P/N

M 365-03

Part Number

4.681 605

Manufacturer

Bohlender

Capillary connections

4

b.safe Waste Cap S65 5x UNF1/4", 1x GL14
Available soon
Bohlender b.safe Waste Cap S65 5x UNF1/4", 1x GL14

NTD 8,488

Inc. VAT

Manufacturer P/N

M 365-01

Part Number

4.681 604

Manufacturer

Bohlender

Capillary connections

5

Frequently asked questions

It is designed for laboratory applications, providing secure connections and high-quality performance. Made of durable polyethylene (PE), it features a freely movable PTFE insert and four UNF 1/4" fittings, one GL14 connection for an exhaust filter (sold separately), and one NPT 1/8" hose connection. This versatile waste cap ensures proper sealing and safety for handling various laboratory fluids, and supports connecting capillaries (O.D. 1.6/2.2/3.2 mm) and hose olives for tubing with inner diameters of 5.5 to 8 mm.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story