Representative Image

Bohlender b.safe Waste Cap S40 2x UNF1/4", 1x GL14, 1x NPT1/8"

Brand:Bohlender

Capillary connections

Connection for exhaust filter

No. of blind plugs

No. of fittings

No. of olives

Specifications

Compare models
Capillary connections
2
Connection for exhaust filter
1
Hose connections
1
Material
PPS
No. of blind plugs
1
No. of fittings
2 x 1,6/ 2,2/ 3,2 mm
No. of olives
1
Thread
S 40
UNSPSC
41115700

NTD 5,057

Inc. VAT

Available soon

Product description

The Bohlender b.safe Waste Cap S40 2x UNF1/4", 1x GL14, 1x NPT1/8" is designed for secure and flexible connections in laboratory systems. It features a freely movable PTFE insert for reliable sealing and easy connection of capillaries with outer diameters of 1.6, 2.2, and 3.2 mm. The cap also includes hose olives compatible with tubing having inner diameters of 5.5 to 8 mm. The GL14 thread allows the attachment of a b.safe exhaust air filter (filter not included), making it suitable for waste systems requiring filtration. Constructed from durable PPS, this waste cap ensures chemical resistance and long-term reliability in laboratory waste management.

Key Features:

  • Brand: Bohlender
  • Material: Durable PPS with PTFE insert for chemical resistance
  • Connections: 2x UNF1/4" fittings (for capillaries O.D. 1.6/2.2/3.2 mm), 1x GL14 thread, 1x NPT1/8" hose olive (for tubing I.D. 5.5 to 8 mm)
  • Application: Ideal for laboratory waste systems and filtration setups
  • Packaging: Sold individually

Scope of Supply:

  • Fittings (UNF 1/4")
  • Blind fitting (UNF 1/4")
  • Hose olive (NPT 1/8")

This waste cap is an essential component for laboratories requiring efficient, secure, and durable waste management solutions.

Accessories

Exhaust Filter, PP

ProductMaterialFilter sizeMfr#Part#AvailabilityPrice
PPSM 506-016.313 839In stockNTD 5,743
PPMM 506-026.313 840In stockNTD 8,344
PPLM 506-036.313 841In stockNTD 10,692

Hose connectors for Waste Caps

ProductMaterialLengthMfr#Part#AvailabilityPrice
PP45 mmM 503-014.681 618NTD 867
PTFE45 mmM 503-054.681 619NTD 1,698
PP30 mmM 503-084.681 620NTD 831
PP32 mmM 503-094.681 621NTD 722
PP23 mmM 503-104.681 622NTD 722
PP26 mmM 503-114.681 623NTD 722
PP26 mmM 503-124.681 624NTD 722
PP30 mmM 503-134.681 625NTD 722
PP36 mmM 503-144.681 626NTD 722
PTFE45 mmM 503-154.681 627NTD 1,770
PP40 mmM 503-164.681 628NTD 722
PP48 mmM 513-014.681 643NTD 722
PP41 mmM 513-024.681 644NTD 722
PP30 mmM 518-014.681 647NTD 795

Compare similar models

b.safe Waste Cap S40 2x UNF1/4", 1x GL14, 1x NPT1/8"

Manufacturer P/N

M 340-03

Part Number

4.681 580

Manufacturer

Bohlender

Capillary connections

2

b.safe Waste Cap S40 3x UNF 1/4", 1x GL 14
Available soon
Bohlender b.safe Waste Cap S40 3x UNF 1/4", 1x GL 14

NTD 5,490

Inc. VAT

Manufacturer P/N

M 340-01

Part Number

4.681 579

Manufacturer

Bohlender

Capillary connections

3

Frequently asked questions

It is designed for secure and flexible connections in laboratory systems. It features a freely movable PTFE insert for reliable sealing and easy connection of capillaries with outer diameters of 1.6, 2.2, and 3.2 mm. The cap also includes hose olives compatible with tubing having inner diameters of 5.5 to 8 mm. The GL14 thread allows the attachment of a b.safe exhaust air filter (filter not included), making it suitable for waste systems requiring filtration. Constructed from durable PPS, this waste cap ensures chemical resistance and long-term reliability in laboratory waste management.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 5,057

Inc. VAT