Representative Image

Bohlender b.safe Removal Cap GL 45 2x UNF 1/4" 28G, PPS / PTFE

Brand:Bohlender

Capillary connections

No. of blind plugs

No. of fittings

Specifications

Compare models
HS Code #
39269097
Capillary connections
1
Material
PPS
No. of blind plugs
0
No. of fittings
1 x 3,2 mm
Thread
GL 45
UNSPSC
41115700

NTD 4,443

Inc. VAT

Available soon

Product description

The Bohlender b.safe Removal Cap GL 45 is engineered for secure and contamination-free solvent handling in laboratories. Designed with 2x UNF 1/4" 28G female threads for connecting capillary tubing (O.D. 3.2 mm) or a b.safe air valve with service life indicator, this cap features a robust PPS body and a freely rotating PTFE distributor insert, ensuring chemical resistance and ease of use.

Key Features:

  • Brand: Bohlender
  • Thread Size: GL 45
  • Connections: 2x UNF 1/4" 28G female threads
  • Material: PPS cap with PTFE insert
  • Application: Ideal for safe solvent extraction and liquid chromatography systems
  • Accessories: Includes fittings, blind plugs, and air valve
  • Capillary Tubing Compatibility: Designed for tubing with outer diameter 3.2 mm
  • Air Valve Feature: Includes service life indicator

Scope of Supply:

  • Connections
  • Fittings (PFA)
  • Blind fittings (PFA)
  • Air valve with service life indicator

This cap is an essential safety solution for liquid transfer systems in analytical and chemical laboratories.

Accessories

Air valves, PP

ProductMaterialØMfr#Part#AvailabilityPrice
PP20 mmM 505-016.313 842In stockNTD 3,034
PP20 mmM 505-026.313 843In stockNTD 10,005
PP20 mmM 505-056.313 844NTD 37,059

Fittings, PFA, for Caps and Waste Caps

ProductMaterialColourMfr#Part#AvailabilityPrice
PFAGreenM 501-064.681 835NTD 2,601
PFAVioletM 501-114.681 836NTD 2,601
PFAGreyM 501-124.681 837NTD 2,601
PFAWhiteM 501-154.681 838NTD 2,637
PFABlueM 501-164.681 839NTD 2,601
PFARedM 501-174.681 840NTD 2,637
PFAYellowM 501-184.681 841NTD 2,601

Compare similar models

b.safe Removal cap GL 45 2x UNF 1/4" 28G, PPS / PTFE

Manufacturer P/N

M 145-01

Part Number

6.313 834

Manufacturer

Bohlender

Capillary connections

1

b.safe Removal cap GL 45 3x UNF 1/4" 28G, PPS / PTFE

Manufacturer P/N

M 145-02

Part Number

6.313 835

Manufacturer

Bohlender

Capillary connections

2

b.safe Removal cap GL 45 4x UNF 1/4" 28G, PPS / PTFE

Manufacturer P/N

M 145-03

Part Number

6.313 836

Manufacturer

Bohlender

Capillary connections

3

b.safe Cap GL45 5x UNF 1/4"
Available soon
Bohlender b.safe Cap GL45 5x UNF 1/4"

NTD 7,260

Inc. VAT

Manufacturer P/N

M 145-04

Part Number

4.681 558

Manufacturer

Bohlender

Capillary connections

4

b.safe Cap GL45 7x UNF 1/4"
Available soon
Bohlender b.safe Cap GL45 7x UNF 1/4"

NTD 7,296

Inc. VAT

Manufacturer P/N

M 145-05

Part Number

4.681 559

Manufacturer

Bohlender

Capillary connections

6

Frequently asked questions

It is engineered for secure and contamination-free solvent handling in laboratories. Designed with 2x UNF 1/4" 28G female threads for connecting capillary tubing (O.D. 3.2 mm) or a b.safe air valve with service life indicator, this cap features a robust PPS body and a freely rotating PTFE distributor insert, ensuring chemical resistance and ease of use.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story