Representative Image

Bohlender b.safe Multiport, PTFE NPT 1/8", 2x UNF 1/4"

Brand:Bohlender

Capillary connections

No. of fittings

Hose connections

No. of olives

Specifications

Compare models
HS Code #
39269097
Capillary connections
2
Hose connections
1
Material
PTFE
No. of fittings
2 x 1,6/2,2/3,2 mm, 90°
No. of olives
1
Thread
NPT 1/8"
UNSPSC
41115700

NTD 4,587

Inc. VAT

Available soon

Product description

The Bohlender b.safe Multiport is designed for efficient and secure solvent waste management in laboratory environments. Constructed from high-quality PTFE, it offers exceptional chemical resistance and durability. This multiport features two UNF 1/4" PFA fittings suitable for capillaries with outer diameters of 1.6 mm, 2.2 mm, and 3.2 mm, and includes a hose olive compatible with tubing inner diameters ranging from 5.5 mm to 8.0 mm. The NPT 1/8" thread ensures a reliable connection to b.safe caps, facilitating safe and organized solvent disposal.

Key Features:

  • Brand: Bohlender
  • Material: PTFE for superior chemical resistance
  • Connections: 2 x UNF 1/4" PFA fittings for capillaries (1.6/2.2/3.2 mm)
  • Hose Connection: 1 x NPT 1/8" hose olive for tubing (I.D. 5.5–8.0 mm)
  • Application: Ideal for safe solvent waste disposal in laboratories
  • Packaging: Sold individually

This multiport is an essential component for laboratories seeking reliable and safe solvent waste management solutions.

Compare similar models

b.safe Multiport, PTFE NPT 1/8", 2x UNF 1/4"
Available soon
Bohlender b.safe Multiport, PTFE NPT 1/8", 2x UNF 1/4"

NTD 4,587

Inc. VAT

Manufacturer P/N

M 509-33

Part Number

4.680 461

Manufacturer

Bohlender

Capillary connections

2

b.safe Multiport, PTFE NPT 1/8", 3x UNF 1/4"
Available soon
Bohlender b.safe Multiport, PTFE NPT 1/8", 3x UNF 1/4"

NTD 2,926

Inc. VAT

Manufacturer P/N

M 509-26

Part Number

4.681 189

Manufacturer

Bohlender

Capillary connections

3

b.safe Multiport, PTFE NPT 1/8", 2x UNF 1/4"

Manufacturer P/N

M 509-25

Part Number

4.681 188

Manufacturer

Bohlender

Capillary connections

2

b.safe Multiport, PTFE NPT 1/8", 8x UNF 1/4"
Available soon
Bohlender b.safe Multiport, PTFE NPT 1/8", 8x UNF 1/4"

NTD 7,730

Inc. VAT

Manufacturer P/N

M 509-28

Part Number

4.681 633

Manufacturer

Bohlender

Capillary connections

8

b.safe Multiport, PTFE NPT 1/8", 3x UNF 1/4", 90°

Manufacturer P/N

M 509-32

Part Number

4.681 635

Manufacturer

Bohlender

Capillary connections

3

b.safe Multiport, PTFE NPT 1/8", 7x UNF 1/4"
Available soon
Bohlender b.safe Multiport, PTFE NPT 1/8", 7x UNF 1/4"

NTD 7,657

Inc. VAT

Manufacturer P/N

M 509-29

Part Number

4.681 634

Manufacturer

Bohlender

Capillary connections

7

b.safe Multiport, PTFE NPT 1/8" (m), 3x NPT 1/8" (f)

Manufacturer P/N

M 509-34

Part Number

4.680 134

Manufacturer

Bohlender

Capillary connections

-

b.safe Multiport, PTFE NPT1/8" (m), 3xNPT1/8" (f), 90°

Manufacturer P/N

M 509-36

Part Number

4.681 636

Manufacturer

Bohlender

Capillary connections

-

Frequently asked questions

It is designed for efficient and secure solvent waste management in laboratory environments. Constructed from high-quality PTFE, it offers exceptional chemical resistance and durability. This multiport features two UNF 1/4" PFA fittings suitable for capillaries with outer diameters of 1.6 mm, 2.2 mm, and 3.2 mm, and includes a hose olive compatible with tubing inner diameters ranging from 5.5 mm to 8.0 mm. The NPT 1/8" thread ensures a reliable connection to b.safe caps, facilitating safe and organized solvent disposal.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story