BINDER Warming Cabinet ED-S 56, 62L, 590x580x515 mm, 230V

Brand:BINDER

Depth int.

Ext. dim. (WxDxH)

Ext. depth

Ext. height

Ext. width

Power supply frequency

Height int.

Int. Dim. (WxDxH)

Int. width

Max. no. of inserts

Max. voltage

Nominal capacity

Plug type

Power supply

Rated capacity

Temperature stability

Temperature

Type

Weight

Specifications

Compare models
HS Code #
90278990
Depth int.
350 mm
Ext. dim. (WxDxH)
614 x 577 x 625 mm
Ext. depth
577 mm
Ext. height
625 mm
Ext. width
614 mm
Power supply frequency
50/60 Hz
Height int.
440 mm
Int. Dim. (WxDxH)
400 x 350 x 440 mm
Int. width
400 mm
IP code
IP 20

NTD 61,548

Inc. VAT

Available soon

Product description

The BINDER Warming Cabinet ED-S 56 offers reliable heating with a 62-liter capacity and natural convection, ensuring even temperature distribution. With robust stainless steel construction and precision control, it’s ideal for sample warming in research and clinical labs.

Key Features:

  • Brand: BINDER
  • Model: ED-S 56
  • Capacity: 62 liters
  • Temperature Range: +7 °C to +250 °C
  • Interior Dimensions: 400 x 350 x 440 mm
  • Exterior Dimensions: 614 x 577 x 625 mm
  • Material: Stainless steel interior
  • Power Supply: 230V, 50/60 Hz
  • Stability: ±0.8 K at 150 °C

Perfect for precise warming tasks in laboratory environments requiring temperature stability and reliability.

Downloads

Accessories

Grid shelves for incubators BD-S and drying and heating chambers ED-S / FD-S

ProductForUNSPSCMfr#Part#AvailabilityPrice
BD-S 56 / ED-S 56 / FD-S 56411045128012-18074.670 815NTD 3,793
BD-S 115 / ED-S 115 / FD-S 115411045128012-18084.668 960NTD 4,623

Compare similar models

Warming cabinet ED-S 56 62 l, 590x580x515 mm, 230 V
Available soon
BINDER Warming Cabinet ED-S 56, 62L, 590x580x515 mm, 230V

NTD 61,548

Inc. VAT

Manufacturer P/N

9090-0014

Part Number

4.665 042

Manufacturer

BINDER

Depth int.

350 mm

Warming cabinet ED-S 115 118 l, 764x735x616 mm, 230 V

Manufacturer P/N

9090-0020

Part Number

4.667 816

Manufacturer

BINDER

Depth int.

390 mm

Drying and Heating Chamber EDS115UL 120V
Available soon
BINDER Drying and Heating Chamber EDS115UL, 120V

NTD 76,791

Inc. VAT

Manufacturer P/N

9090-0021

Part Number

4.705 564

Manufacturer

BINDER

Depth int.

390 mm

Drying and Heating Chamber EDS056UL 120V
Available soon
BINDER Drying and Heating Chamber EDS056UL, 120V

NTD 61,548

Inc. VAT

Manufacturer P/N

9090-0015

Part Number

4.705 563

Manufacturer

BINDER

Depth int.

350 mm

More items to explore

Drying and heating chambers FD-S Solid.Line

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUFD-S 569090-00184.665 196NTD 75,021
EUFD-S 1159090-00244.665 522NTD 97,849
USFD-S 56UL9090-00194.705 567NTD 75,021
USFD-S 115UL9090-00254.705 568NTD 97,849

Drying and heating chambers ED Classic.Line

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUED 239010-01909.883 529NTD 88,386
CEEED 4009010-00759.883 551NTD 252,081
USED 23UL9010-01929.883 612NTD 88,386
USED 400UL9010-01684.705 562NTD 252,081

Frequently asked questions

It offers reliable heating with a 62-liter capacity and natural convection, ensuring even temperature distribution. With robust stainless steel construction and precision control, it’s ideal for sample warming in research and clinical labs.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story