Representative Image

Behr Labor-Technik Rapid Infrared Digestion Unit InKjel 450 TCP for 4 Sample Vessels of 500ml, with Temperature Control

Max. no. of sample positions

Nominal capacity per position

Type

Specifications

Compare models
Power supply frequency
50/60 Hz
Max. no. of sample positions
4
Max. temperature
830 °C
Max. voltage
230 V·AC
Nominal capacity per position
500 ml
Power supply
230 V·AC, 50/60 Hz
Rated capacity
1500 W
Type
InKjel 450 TCP
UNSPSC
41104815

NTD 291,922

Inc. VAT

Available soon

Product description

The Behr Labor-Technik Rapid Infrared Digestion Unit InKjel 450 TCP is a high-performance device designed for rapid digestion of samples in laboratory settings. Equipped with a temperature control feature, it allows for precise heating of up to 4 sample vessels of 500ml, making it ideal for applications that require controlled, rapid digestion processes.

Key Features:

  • Brand: Behr Labor-Technik
  • Model: InKjel 450 TCP
  • Capacity: Supports up to 4 sample vessels of 500ml
  • Temperature Control: Precise temperature control for optimal digestion conditions
  • Heating Technology: Utilizes rapid infrared heating for efficient sample digestion
  • Applications: Perfect for Kjeldahl digestion, environmental testing, and chemical analysis
  • Design: Compact design suitable for laboratory use with excellent safety and user-friendly features

The Behr Labor-Technik Rapid Infrared Digestion Unit InKjel 450 TCP ensures efficient, controlled digestion of samples, providing reliable results for a variety of analytical tasks.

Downloads

Compare similar models

Rapid Infrared digestion unit InKjel 450 TCP for 4 sample vessels of 500 ml with temperature control

Manufacturer P/N

B00636209

Part Number

9.843 709

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

4

Rapid Infrared digestion unit InKjel 625 TCP for 6 sample vessels of 250 ml with temperature control

Manufacturer P/N

B00636206

Part Number

9.843 706

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

6

Rapid Infrared digestion unit InKjel 1225 TCP for 12 sample vessels of 250 ml with temperature control

Manufacturer P/N

B00636208

Part Number

9.843 708

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

12

Rapid Infrared digestion unit InKjel 1210 TCP for 12 sample vessels of 100 ml with temperature cotnrol

Manufacturer P/N

B00636207

Part Number

9.843 707

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

12

Rapid Infrared digestion unit InKjel 475 TCP for 4 sample vessels of 750 ml with temperature control

Manufacturer P/N

B00636210

Part Number

9.843 710

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

4

Frequently asked questions

It is a high-performance device designed for rapid digestion of samples in laboratory settings. Equipped with a temperature control feature, it allows for precise heating of up to 4 sample vessels of 500ml, making it ideal for applications that require controlled, rapid digestion processes.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 291,922

Inc. VAT