Representative Image

2mag atexMIXdrive 1 (Only Available with Firmly Mounted Control Unit)

Brand:2mag

Plug type

Specifications

Compare models
Depth
180 mm
Dimensions (WxDxH)
180 x 180 x 38 mm
Height
38 mm
IP code
IP 68
Material housing
Stainless steel
Material stirring surface
Stainless steel
Max. permitted ambient temp.
40 °C
Max. stirring capacity
10 l
Max. voltage
48 V·DC
Min. permitted ambient temperature
-10 °C

NTD 92,395

Inc. VAT

Available soon

Product description

The 2mag atexMIXdrive 1 (Only Available with Firmly Mounted Control Unit) is an explosion-protected magnetic stirrer designed for safe and reliable liquid mixing in hazardous laboratory and industrial environments. Featuring one stirring position with a maintenance-free, wear-free inductive drive, this unit delivers powerful and jerk-free stirring, even at low speeds. Its very robust, completely sealed stainless steel housing offers maximum resistance and easy cleaning, making it well suited to demanding applications where durability and certified safety are essential.

Key Features:

  • Brand: 2mag
  • Model: atexMIXdrive 1
  • Stirring Positions: 1 stirring position
  • Drive Type: Maintenance-free, wear-free inductive drive
  • Stirring Performance: Powerful, jerk-free stirring, even at low speed
  • Construction: Very robust, easy-to-clean design with maximum resistance
  • Housing Material: Completely sealed stainless steel housing
  • Protection: Water-, dust-, and germproof magnetic stirrer
  • Application Compatibility: Suitable for use in water baths, oil baths, CO2 incubators, and ovens
  • Certification: Certified according to ATEX II 2G Ex mb IIC T4 Gb

Note: The magnetic stirrer can only be used together with a control unit, which must be ordered separately. The magnetic stirrer, control unit, and power supply are firmly connected to each other to ensure Ex protection.

The 2mag atexMIXdrive 1 (Only Available with Firmly Mounted Control Unit) is a practical choice for laboratories and controlled environments where explosion protection, robust construction, and dependable stirring performance are required. Its sealed stainless steel design and ATEX-certified configuration make it especially suitable for demanding applications involving hazardous, sensitive, or temperature-controlled processes.

Accessories

Accessories for mixer MIXdrive

ProductDescriptionUNSPSCMfr#Part#AvailabilityPrice
mixBATH PC, fits for MIXdrive 6/15/60 to 50 °C41103816408506.286 233NTD 35,109
mixBATHcover 15, PP, for mixBath in combination with MIXdrive 1541103816408156.255 612NTD 20,841
mixBATHcover 6, PP, for mixBath in combination with MIXdrive 641103816408067.639 439NTD 20,841
distriBOX 4 (4-way header)41103816490049.645 972NTD 16,001
distriBOX 8 (8-way header)41103816490089.645 973NTD 22,611
mixBATH (stainless steel bath, electropolished), fits for MIXdrive 6/15/60 (also HT)41103816409509.645 974NTD 44,175

Control unit atexMIXcontrol

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUatexMIXcontrol992006.238 006NTD 271,984

Compare similar models

atexMIXdrive 1 Only with firmly mounted controll unit available!

Manufacturer P/N

49001

Part Number

6.238 005

Manufacturer

2mag

Plug type

EU

atexMIXdrive 1 magnetic stirring system with UK plug Only with firmly mounted controll unit available!

Manufacturer P/N

49001 UK

Part Number

6.311 203

Manufacturer

2mag

Plug type

UK

Frequently asked questions

It is an explosion-protected magnetic stirrer designed for safe and reliable liquid mixing in hazardous laboratory and industrial environments. Featuring one stirring position with a maintenance-free, wear-free inductive drive, this unit delivers powerful and jerk-free stirring, even at low speeds. Its very robust, completely sealed stainless steel housing offers maximum resistance and easy cleaning, making it well suited to demanding applications where durability and certified safety are essential.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 92,395