Representative Image

Xylem WTW Multiparameter Meter Multi 3620 IDS Set G

Brand:Xylem WTW

Specifications

HS Code #
90330090
Depth
180 mm
Dimensions (WxDxH)
80 x 180 x 55 mm
Power supply frequency
50/60 Hz
Height
55 mm
Interfaces
USB-A, Mini USB-B
IP code
IP 67
Max. voltage
240 V
Min. voltage
100 V
Power supply
100 ... 240 V, 50/60 Hz
Type
Multi 3620 Set G

Alternative in-stock items

NTD 170,306

Inc. VAT

Available soon

Product description

The Xylem WTW MultiLine Multi 3620 IDS Set G is a versatile, portable multiparameter meter designed for precise field measurements. Equipped with two universal measuring channels, it allows simultaneous digital measurement of pH, ORP, dissolved oxygen, and turbidity. The set includes high-quality IDS sensors: the digital pH sensor SenTix 940-3, the optical dissolved oxygen sensor FDO 925-3, and the digital conductivity cell TetraCon 925-3, ensuring accurate and reliable data collection in various environmental conditions.

Key Features:

  • Brand: Xylem WTW
  • Model: MultiLine Multi 3620 IDS Set G
  • Measurement Channels: 2 universal channels for simultaneous measurement
  • Compatible Parameters: pH, ORP, dissolved oxygen, turbidity
  • Included Sensors: SenTix 940-3 (pH), FDO 925-3 (DO), TetraCon 925-3 (conductivity)
  • Display: LCD color graphic, backlit
  • Data Memory: 500 manual / 10,000 automatic records
  • Interfaces: Mini-USB-B, USB-A
  • Power Supply: 4x 1.2 V NiMH batteries or via Mini USB-B
  • Protection Class: IP 67 (dust-tight and waterproof)
  • Application: Ideal for field measurements in environmental monitoring, water quality testing, and research
  • Packaging: Supplied in a large carrying case with accessories
  • Product Overview: The Xylem WTW MultiLine Multi 3620 IDS Set G is a versatile, portable multiparameter meter designed for precise field measurements.

This comprehensive set is essential for professionals requiring accurate and durable equipment for multiparameter measurements in diverse field conditions.

Downloads

Accessories

IDS conductivity cell probes TetraCon® 925/LV

ProductTypeMax. temperatureMfr#Part#AvailabilityPrice
TetraCon ® 925/LV100 °C3017186.269 370NTD 46,161
TetraCon ® 925/LV-P100 °C3017196.318 157NTD 47,389

Optical D.O. Sensor FDO® 925

ProductTypeIntake capacityMfr#Part#AvailabilityPrice
FDO ® 9250 ... 20 mg/l (20 °C)2013006.238 174NTD 59,923
FDO ® 925-30 ... 20 mg/l (20 °C)2013016.239 577NTD 61,151
FDO ® 925-P0 ... 20 mg/l (20 °C)2013066.259 423NTD 61,260

More items to explore

Multiparameter meter MultiLine® 3620 IDS

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
Multi 3620Mains connection/rechargeable battery2FD5606.282 919In stockNTD 81,414

Frequently asked questions

It is a versatile, portable multiparameter meter designed for precise field measurements. Equipped with two universal measuring channels, it allows simultaneous digital measurement of pH, ORP, dissolved oxygen, and turbidity. The set includes high-quality IDS sensors: the digital pH sensor SenTix 940-3, the optical dissolved oxygen sensor FDO 925-3, and the digital conductivity cell TetraCon 925-3, ensuring accurate and reliable data collection in various environmental conditions.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story