Representative Image

Vacuubrand Vacuum Gauge Set DCP 3000, Complete with Cable and Sensor VSK 3000, 100-230 V, 50/60 Hz, CEE

Specifications

Depth
124 mm
Dimensions (WxDxH)
144 x 124 x 114 mm
Power supply frequency
50/60 Hz
Height
114 mm
Max. measured value
1080 mbar
Max. permitted ambient temp.
40 °C
Max. voltage
230 V
Measured range
0.1 ... 1,080 mbar
Min. measured value
0.1 mbar
Min. permitted ambient temperature
10 °C

NTD 76,322

Inc. VAT

Available soon

Product description

The Vacuubrand Vacuum Gauge Set DCP 3000 is a comprehensive vacuum measurement solution, complete with a high-quality cable and the VSK 3000 sensor. Designed for accurate and reliable vacuum measurements, this set is ideal for laboratory and industrial applications. It operates with a 100-230 V, 50/60 Hz CEE power supply, ensuring versatile compatibility for various regions.

Key Features:

  • Brand: Vacuubrand
  • Model: DCP 3000 with VSK 3000 Sensor
  • Voltage: 100-230 V, 50/60 Hz
  • Power Supply: CEE Mains Cable
  • Application: Ideal for vacuum measurement in laboratory and industrial environments
  • Includes: Vacuum Gauge, Cable, and Sensor for complete setup

Enhance your vacuum measurement capabilities with the Vacuubrand Vacuum Gauge Set DCP 3000, designed for precision and reliability in a wide range of applications.

Downloads

Accessories

Accessories for Vacuum Controller VACUU·SELECT and Measuring instrument DCP 3000

ProductDescriptionUNSPSCMfr#Part#AvailabilityPrice
Extension cable for VACUU·BUS®, 2m40151502206125529.882 853NTD 2,745
Liquid level sensor for VACUUBRAND catchpot 500 ml40151502206999089.882 848NTD 27,343
Y-adapter for VACUU·BUS ®40151502206832406.284 162NTD 8,488
Extension cable VACUU·BUS®, 4-pol., 10 m40151502226184936.252 487NTD 8,560
VACUU·BUS® wall feedthrough (plug-socket), for wall thickness of 1 - 10 mm40151502206361534.669 820NTD 6,177
Digital-I/O-Module VACUU·BUS®40151502206362284.669 827NTD 18,385
Analog-I/O-Module VACUU·BUS®40151502206362294.661 327NTD 19,396
VMS-B module for vacuum controller CVC 3000 to switch a vacuum pump40151502206760307.940 071NTD 29,510

Accessories for Vacuum Controller VACUU·SELECT and Measuring instrument DCP 3000

ProductTypeDescriptionMfr#Part#AvailabilityPrice
VKW-BCooling water valve VKW-B206742209.882 852NTD 18,385
VBM-BAir admittance valve VBM-B206742179.882 849NTD 20,408
VV-B 6CSolenoid inline valve VV-B 6C206742919.882 851NTD 36,264
VV-B 6Solenoid inline valve VV-B 6206742906.239 120NTD 19,360
VV-B 15CSolenoid inline valve VV-B 15C with KF DN 25206742156.231 611NTD 48,184
VV-B 15CSolenoid inline valve VV-B 15C with KF DN 16206742104.670 300NTD 47,173

More items to explore

Vacuum measuring instrument DCP 3000 with Pirani sensor VSP 3000

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EU/UK/CH/US/AUS/CNDCP 3000 + VSP 3000206831909.882 207NTD 74,949

Frequently asked questions

It is a comprehensive vacuum measurement solution, complete with a high-quality cable and the VSK 3000 sensor. Designed for accurate and reliable vacuum measurements, this set is ideal for laboratory and industrial applications. It operates with a 100-230 V, 50/60 Hz CEE power supply, ensuring versatile compatibility for various regions.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 76,322

Inc. VAT