Representative Image

VACUUBRAND Rotary Vane Pump RE 2.5, One Stage, Inlet KF DN 16 / Hose Nozzle DN 10 mm, 220 to 230 V/50 to 60 Hz, 100 to 115 V/50 to 60 Hz,120 V/60 Hz, US Mains Cable

Max. voltage

Plug type

Power supply

Specifications

Compare models
HS Code #
84141025
Connection pressure side
DN 8-10 mm
Connection suction side
KF DN 16
Depth
390 mm
Dimensions (WxDxH)
156 x 390 x 240 mm
Flow rate
38.33 l/min
Power supply frequency
50/60 Hz
Height
240 mm
IP code
IP 40
Max. voltage
115 V
Min. voltage
100 V

NTD 91,709

Inc. VAT

Available soon

Product description

The VACUUBRAND Rotary Vane Pump RE 2.5, one-stage, inlet KF DN 16 / hose nozzle DN 10 mm, 220-230 V/50-60 Hz, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable is a rotary vane vacuum pump from VACUUBRAND designed for oil-sealed vacuum generation for laboratory and industrial processes. Scope of supply: Rotary vane pump, manual. Its documented configuration includes electrical supply: 220-230 V, 100-115 V, 120 V, 50-60 Hz, 60 Hz, connection: US Mains Cable, and pump design: One-Stage.

Key Features:

  • Brand: VACUUBRAND
  • Model: RE 2.5
  • Product Type: Rotary Vane Vacuum Pump
  • Electrical Supply: 220-230 V, 100-115 V, 120 V, 50-60 Hz, 60 Hz
  • Connection: US Mains Cable
  • Pump Design: One-Stage
  • Included Items: Rotary vane pump, manual

The VACUUBRAND Rotary Vane Pump RE 2.5, one-stage, inlet KF DN 16 / hose nozzle DN 10 mm, 220-230 V/50-60 Hz, 100-115 V/50-60 Hz, 120 V/60 Hz, US Mains Cable supports oil-sealed vacuum generation for laboratory and industrial processes where the stated configuration is required. Confirm process compatibility, wetted materials, electrical supply, connections, and included components before ordering.

Accessories

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081NTD 3,973
PVC34.9 mm206860634.714 084NTD 10,114
PVC38.1 mm206860654.714 085NTD 11,811
PVC15.9 mm206860614.714 082NTD 4,659
PVC22.3 mm206860624.714 083NTD 5,526

Compare similar models

Rotary vane pump RE 2.5, one stage, inlet KF DN 16 / hose nozzle DN 10 mm, 220-230 V/50-60 Hz, 100-115 V/50-60 Hz,120 V/60 Hz, US mains cable

Manufacturer P/N

20797156

Part Number

4.691 578

Manufacturer

VACUUBRAND​

Max. voltage

115 V

Rotary vane pump RE 2.5 one stage 230 V / 50-60 HZ, UK/IN mains cable

Manufacturer P/N

20797152

Part Number

4.691 576

Manufacturer

VACUUBRAND​

Max. voltage

230 V

Rotary vane pump RE 2.5 one stage 230 V / 50-60 HZ, CH/CN mains cable

Manufacturer P/N

20797151

Part Number

4.691 575

Manufacturer

VACUUBRAND​

Max. voltage

230 V

Rotary vane pump RE 2.5 one stage 230 V / 50-60 HZ, CEE mains cable

Manufacturer P/N

20797150

Part Number

4.691 574

Manufacturer

VACUUBRAND​

Max. voltage

230 V

More items to explore

Rotary vane pump RZ 2.5, two-stage

Rotary vane pump RZ 2.5, two-stage, package

Frequently asked questions

It is a rotary vane vacuum pump from VACUUBRAND designed for oil-sealed vacuum generation for laboratory and industrial processes. Scope of supply: Rotary vane pump, manual.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story