Representative Image

SI Analytics Titroline TL 5000/20 M3 Basic Unit, w.pH-electrode+buffer Set, With Dosing Unit 20 mL TZ 3130, Magnetic Stirrer TM 50,

Specifications

HS Code #
90278990
Accuracy pH
0.05
Accuracy pH
±0.05
Depth
205 mm
Dimensions (WxDxH)
135 x 205 x 310 mm
Dosing accuracy
0.15 R%
Dosing volume
20 ml
Power supply frequency
50/60 Hz
Height
310 mm
Max. temperature
115 °C
Max. voltage
240 V

NTD 187,138

Inc. VAT

Available soon

Product description

The SI Analytics Titroline TL 5000/20 M3 Basic Unit, w.pH-electrode+buffer Set, With Dosing Unit 20 mL TZ 3130, Magnetic Stirrer TM 50, is designed for mixing of laboratory solutions and suspensions with 20 mL. This SI Analytics stirrer supports reliable laboratory and scientific workflows.

Key Features:

  • Brand: SI Analytics
  • Product Type: Stirrer
  • Capacity: 20 mL
  • Design: Scope of supply: Basic unit with ready to use assembled 20 ml dosing unit TZ 3130 with hoses, fittings and titration tip, controller TZ 3880, titration clamp Z 305, stand rod TZ 1748 magnetic stirrer...
  • Application: Mixing of laboratory solutions and suspensions

This SI Analytics stirrer is suitable for laboratories requiring trusted performance, accurate output, and dependable laboratory use.

Downloads

Accessories

Accessories for TITRONIC® / TitroLine®

ProductTypeDescriptionMfr#Part#AvailabilityPrice
TM 235Magnetic stirrer2852204009.863 154NTD 37,637

Frequently asked questions

It is designed for mixing of laboratory solutions and suspensions with 20 mL. This SI Analytics stirrer supports reliable laboratory and scientific workflows.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.