Representative Image

SCAT SafetyWasteCap "LISA" Quick-Lock Connector / Justrite

Brand:SCAT

Specifications

Capillary connections
4
Connection for exhaust filter
1
Hose connections
3
Material
PTFE
No. of fittings
4x1,6/2,3/3,2 mm
No. of olives
3
Thread
CPC
UNSPSC
41115700

NTD 10,403

Inc. VAT

Available soon

Product description

The SCAT SafetyWasteCap "LISA" Quick-Lock Connector / Justrite is designed to provide a secure, vapor-tight connection between laboratory waste containers and SCAT safety systems. Featuring a user-friendly quick-lock mechanism, this cap ensures easy, safe handling of liquid waste while preventing exposure to harmful vapors. It is fully compatible with Justrite canisters and ideal for high-safety lab environments.

Key Features:

  • Brand: SCAT
  • Model: "LISA" SafetyWasteCap with Quick-Lock Connector
  • Compatibility: Works with Justrite canisters and SCAT systems
  • Function: Secure, vapor-tight waste management
  • Design: Quick-lock connector for easy and safe operation
  • Connection: Safety Waste Cap, with Quick-Lock connector, for connecting 4 capillaries (UNF 1/4" 28 G), 3 tube connectors (NPT 1/8") and an exhaust filter (GL 14).

Scope of Supply:

  • Screw cap
  • Satellite (PTFE, white)
  • Blind plug M 30x35 (PTFE)
  • PFA fittings: 4 x 1.6 mm (green), 4 x 2.3 mm (violet), 4 x 3.2 mm (blue)
  • 4 blind plugs for capillary connections (PFA, transparent)
  • 3 tube connectors for tubes with 5.0 - 11.5 mm ID (PP, blue)
  • 3 blind plugs for tube connections (PTFE, white)
  • 1 blind plug GL 14 (PTFE, white)

The SCAT SafetyWasteCap "LISA" with Quick-Lock Connector is the optimal solution for laboratories seeking a safe and user-friendly way to manage liquid chemical waste.

Downloads

Accessories

Exhaust filters V3.0, with change indicator

Tube fittings for the tube connector Safety Waste Caps

ProductMaterialInt. tubing ØMfr#Part#AvailabilityPrice
PP6.4 ... 9.0 mm1178087.940 304NTD 1,011
PP3.0 ... 4.0 mm1078124.005 558NTD 867
PP6.0 ... 8.0 mm1178164.005 793NTD 867
PTFE6.4 ... 8.0 mm1601434.005 868NTD 2,131
PTFE6.4 ... 8.0 mm1601424.005 867NTD 1,698
PP4.0 ... 6.0 mm1078134.005 559NTD 867
PP9.5 ... 11.0 mm1078174.005 562NTD 867
PP9.5 ... 10.0 mm1078104.005 556NTD 867
PP2.0 ... 3.0 mm1078114.005 557NTD 867
PP6.2 ... 7.5 mm1078164.005 561NTD 867
PP5.0 ... 7.0 mm1078144.005 560NTD 867
PP6.4 ... 8.0 mm1078084.005 555NTD 867

More items to explore

Safety Waste Caps V3.0, electrostatic conductive

ProductMaterialCapillary connectionsMfr#Part#AvailabilityPrice
HDPE44500454.683 852NTD 11,667
HDPE44500604.683 853NTD 11,667
HDPE44500554.687 096NTD 11,667
HDPE44500704.687 097NTD 11,667
HDPE44500504.687 095NTD 11,667

Frequently asked questions

It is designed to provide a secure, vapor-tight connection between laboratory waste containers and SCAT safety systems. Featuring a user-friendly quick-lock mechanism, this cap ensures easy, safe handling of liquid waste while preventing exposure to harmful vapors. It is fully compatible with Justrite canisters and ideal for high-safety lab environments.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 10,403

Inc. VAT