Macherey-Nagel EC HPLC Column EC 50/2 NUCLEODUR PFAS Delay, 5 µm Length 50 mm, ID 2 mm

Specifications

HS Code #
84799070
Eluent in column
Acetonitrile/water
Endcapped
Yes
Int. Ø
2 mm
Length
50 mm
Material column
Stainless steel
Max. temp. resistance
60 °C
Method
Analytical
Particle size
5 µm
Particle type
Fully porous
pH stability
1 ... 9

NTD 38,504

Inc. VAT

Available soon

Product description

The Macherey EC HPLC Column EC 50/2 NUCLEODUR PFAS Delay, 5 µm, Length 50 mm, Internal Diameter 2 mm is designed to trap and delay system-related PFAS contaminants, supporting trace-level PFAS analysis in laboratory samples. This column is made from high purity NUCLEODUR HPLC silica gel and is extensively endcapped for reliable performance in high sensitivity LC/MS workflows.

Key Features:

  • Brand: Macherey
  • Column Type: EC HPLC column
  • Model: EC 50/2 NUCLEODUR PFAS Delay
  • Particle Size: 5 µm
  • Length: 50 mm
  • Internal Diameter: 2 mm
  • Material: High purity NUCLEODUR HPLC silica gel
  • Design: Extensively endcapped with low bleeding characteristics
  • Application: Traps and delays system-related PFAS contaminants for trace-level PFAS analysis
  • Analysis Type: Suitable for high sensitivity LC/MS analysis

This NUCLEODUR PFAS Delay EC HPLC column is suitable for laboratories requiring reliable PFAS contaminant delay performance during sensitive trace-level analysis.

Frequently asked questions

The EC 50/2 NUCLEODUR PFAS Delay is designed for traps and delays system-related PFAS contaminants for trace-level PFAS analysis. The stated format and features make the product suitable for routine laboratory work within that application.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story