DOSTMANN LOG40 PDF Data Logger, with Display for Temperature and External Sensors

Brand:Dostmann

Specifications

Battery/ rechargeable battery
2 x 1.5 V, AAA
Depth
100 mm
Designation ANSI
AAA
Dimensions (WxDxH)
40 x 100 x 16 mm
Disposable
No
Height
16 mm
IP code
IP 65
Material housing
ABS
Max. temperature
60 °C
Max. voltage battery/ rechargeable battery
1.5 V

NTD 3,829

Inc. VAT

Available soon

Product description

Dostmann LOG40 PDF Data Logger with Display is designed for precise monitoring, alarming, and recording of temperature, with the option to connect external sensors for measuring relative humidity and pressure. Ideal for use during transport and storage, this data logger provides reliable, traceable documentation of environmental conditions. It automatically generates PDF and Excel reports without requiring additional software, ensuring fast and convenient data analysis for HACCP-compliant applications.

Key Features:

  • Brand: Dostmann
  • Measurement Parameters: Temperature, optional humidity, and pressure with external sensors
  • Display: LCD showing current values, Max-Min readings, and alarm indicators
  • Accuracy: ±0.5 °C at -10 to 60 °C
  • Recording Interval: Adjustable from 1 second to 24 hours
  • Memory Capacity: Up to 40,000 data records
  • Connectivity: USB interface for direct PC connection
  • Data Output: Automatic generation of PDF and Excel reports
  • Calibration: Supplied with calibration certificate
  • Power Supply: Operates on 2 × AAA batteries (included)
  • Compliance: HACCP-compliant according to DIN EN 12830
  • Software: Free LogConnect software for configuration and analysis
  • Application: Monitoring temperature and environmental conditions during transport, storage, and quality control

Note: External sensors for measuring relative humidity and pressure can be connected via the USB port. Please order separately.

Scope of Supply: PDF data logger, 2 × AAA batteries, USB protection cap, mounting kit, and calibration certificate.

The Dostmann LOG40 PDF Data Logger delivers reliable, easy-to-access environmental monitoring, making it the ideal choice for transport validation, warehouse storage, and industrial quality control applications.

Accessories

Temperature probe for PDF data logger LOG40

ProductMax. temperatureMin. temperatureMfr#Part#AvailabilityPrice
125 °C-40 °C6040-04014.691 798NTD 1,409

Combination probe temperature/humidity for PDF data logger LOG40

ProductMax. temperatureMin. temperatureMfr#Part#AvailabilityPrice
70 °C-40 °C6020-00434.691 799NTD 1,553

Frequently asked questions

Dostmann LOG40 PDF Data Logger with Display is designed for precise monitoring, alarming, and recording of temperature, with the option to connect external sensors for measuring relative humidity and pressure. Ideal for use during transport and storage, this data logger provides reliable, traceable documentation of environmental conditions. It automatically generates PDF and Excel reports without requiring additional software, ensuring fast and convenient data analysis for HACCP-compliant applications.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 3,829

Inc. VAT