Representative Image

Bohlender b.safe Waste Cap B53 4x UNF1/4", 1x GL14, 1x NPT1/8"

Brand:Bohlender

Specifications

Capillary connections
4
Connection for exhaust filter
1
Hose connections
1
Material
PE
No. of blind plugs
3
No. of fittings
4 x 1,6/ 2,2/ 3,2 mm
No. of olives
1
Thread
B 53
UNSPSC
41115700

NTD 11,233

Inc. VAT

Available soon

Product description

The Bohlender b.safe Waste Cap B53 4x UNF1/4", 1x GL14, 1x NPT1/8" is a versatile and durable screw cap designed for secure laboratory use. It features a freely movable PTFE insert that ensures reliable sealing and easy connection of capillaries and hoses. Made from high-quality PE (Polyethylene), this waste cap includes four capillary connections (for tubing with outer diameters of 1.6, 2.2, and 3.2 mm), a GL14 thread for an optional b.safe exhaust air filter (filter not included), and one hose connection (NPT 1/8") suitable for tubing with an inner diameter of 5.5 to 8 mm. The B53 thread ensures compatibility with a wide range of solvent storage and handling containers, providing a secure and leak-proof solution for laboratory waste management.

Key Features:

  • Brand: Bohlender
  • Material: PE (Polyethylene) for durability and chemical resistance
  • Insert: Freely movable PTFE insert for reliable sealing
  • Capillary Connections: 4x UNF1/4" fittings (for tubing with O.D. 1.6/2.2/3.2 mm)
  • Exhaust Filter Connection: 1x GL14 thread (filter not included)
  • Hose Connection: 1x NPT1/8" fitting with hose olive (for tubing I.D. 5.5 to 8 mm)
  • Thread: B53

Scope of Supply:

  • Fittings for capillaries
  • Blind fittings (UNF 1/4")
  • Hose olive (NPT 1/8")

This waste cap is essential for efficient and safe solvent and chemical waste management in laboratory environments, ensuring secure and adaptable connections.

Downloads

Accessories

Exhaust Filter, PP

ProductMaterialFilter sizeMfr#Part#AvailabilityPrice
PPSM 506-016.313 839In stockNTD 5,743
PPMM 506-026.313 840In stockNTD 8,344
PPLM 506-036.313 841In stockNTD 10,692

Hose connectors for Waste Caps

ProductMaterialLengthMfr#Part#AvailabilityPrice
PP45 mmM 503-014.681 618NTD 867
PTFE45 mmM 503-054.681 619NTD 1,698
PP30 mmM 503-084.681 620NTD 831
PP32 mmM 503-094.681 621NTD 722
PP23 mmM 503-104.681 622NTD 722
PP26 mmM 503-114.681 623NTD 722
PP26 mmM 503-124.681 624NTD 722
PP30 mmM 503-134.681 625NTD 722
PP36 mmM 503-144.681 626NTD 722
PTFE45 mmM 503-154.681 627NTD 1,770
PP40 mmM 503-164.681 628NTD 722
PP48 mmM 513-014.681 643NTD 722
PP41 mmM 513-024.681 644NTD 722
PP30 mmM 518-014.681 647NTD 795

Frequently asked questions

It is a versatile and durable screw cap designed for secure laboratory use. It features a freely movable PTFE insert that ensures reliable sealing and easy connection of capillaries and hoses. Made from high-quality PE (Polyethylene), this waste cap includes four capillary connections (for tubing with outer diameters of 1.6, 2.2, and 3.2 mm), a GL14 thread for an optional b.safe exhaust air filter (filter not included), and one hose connection (NPT 1/8") suitable for tubing with an inner diameter of 5.5 to 8 mm. The B53 thread ensures compatibility with a wide range of solvent storage and handling containers, providing a secure and leak-proof solution for laboratory waste management.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 11,233

Inc. VAT