Representative Image

Bandelin HF Generator GM 5000 for HD 5020/5050/5100/5200

Brand:Bandelin

Specifications

HS Code #
84799070
Amplitude
10 ... 100 %
Depth
380 mm
Dimensions (WxDxH)
195 x 380 x 215 mm
Power supply frequency
50/60 Hz
Height
215 mm
IP code
IP 30
Max. amplitude
100 %
Max. voltage
230 V
Min. amplitude
10 %
Plug type
EU

NTD 129,093

Inc. VAT

Available soon

Product description

The Bandelin HF Generator GM 5000 is a high-performance ultrasonic generator engineered for precision and reliability. Designed for use with SONOPULS ultrasonic transducers of the UW 5000 series, it efficiently converts low-frequency mains voltage into high-frequency energy for powerful ultrasonic processing. This generator supports applications such as homogenisation, emulsification, deagglomeration, suspension preparation, chemical acceleration, and cell disruption—making it indispensable for laboratory and industrial environments.

Key Features:

  • Brand: Bandelin
  • Model: HF Generator GM 5000
  • Compatibility: For use with SONOPULS ultrasonic transducers of the UW 5000 series
  • Function: Converts low-frequency mains voltage into high-frequency ultrasonic energy
  • Applications: Ideal for homogenisation, deagglomeration, emulsification, suspension, chemical reaction acceleration, and cell disruption
  • Display: 7” colour touch display with intuitive, user-friendly operation
  • Control: Adjustable amplitude and pulse intervals; timer or continuous operation
  • Memory: Up to 8 programmable memory slots for custom settings
  • Connectivity: USB and Ethernet interface for easy data management
  • Construction: Sturdy plastic housing for durability and stability

Note: Please order compatible ultrasonic transducers and sonotrodes separately.

The Bandelin HF Generator GM 5000 ensures precise ultrasonic performance, combining intuitive operation with robust construction for advanced laboratory and industrial applications.

Accessories

Sonotrodes for ultrasonic homogenisers SONOPULS HD 5050 / SONOPULS HD 4000 series

ProductTypeMax. working volumeMfr#Part#AvailabilityPrice
TS 219900 ml37476.288 746NTD 20,299
TS 10325 ml37419.650 158NTD 11,595
TS 4161000 ml37539.650 169NTD 23,659
TS 10220 ml37409.650 157NTD 12,606
TS 10450 ml37429.650 159NTD 11,269
TT 213200 ml37507.910 655NTD 4,443
TS 413750 ml37526.274 618NTD 22,033
TS 216900 ml37466.291 817NTD 17,121
TS 113200 ml37457.647 594NTD 9,500
TS 109100 ml37447.647 593NTD 9,752
TS 2251000 ml37484.667 741NTD 13,437
TS 4191500 ml37544.667 742NTD 25,248
TS 4322500 ml37564.667 744NTD 39,299
TS 4252000 ml37554.667 743NTD 26,368
TS 4383000 ml37574.667 745NTD 42,730

Sonotrodes for ultrasonic homogenisers SONOPULS mini20 / SONOPULS HD 5020

ProductTypeMax. working volumeMfr#Part#AvailabilityPrice
MS 1.510 ml36399.650 165NTD 8,705
MS 2.020 ml36546.251 521NTD 8,344
MS 2.525 ml36529.650 166NTD 8,055

Frequently asked questions

It is a high-performance ultrasonic generator engineered for precision and reliability. Designed for use with SONOPULS ultrasonic transducers of the UW 5000 series, it efficiently converts low-frequency mains voltage into high-frequency energy for powerful ultrasonic processing. This generator supports applications such as homogenisation, emulsification, deagglomeration, suspension preparation, chemical acceleration, and cell disruption, making it indispensable for laboratory and industrial environments.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story