Representative Image

Vacuubrand Chemistry Vacuum System MD 4C NT +AK+EK, Three-Stage, Certification NRTL C/US, 230V, 50-60Hz, UK/IN Mains Cable

Plug type

Specifications

Compare models
HS Code #
84141089
Depth
326 mm
Dimensions (WxDxH)
243 x 326 x 402 mm
Flow rate
3.4 m³/h
Height
402 mm
Plug type
UK
Type
MD 4C NT + AK + EK
Ultimate vacuum
1.5 mbar
Ultimate vacuum with gas ballast
3 mbar
UNSPSC
40151502
Width
243 mm

Alternative in-stock items

NTD 288,454

Inc. VAT

Available soon

Product description

The Vacuubrand Chemistry Vacuum System MD 4C NT +AK+EK is a high-performance three-stage diaphragm pump system designed for demanding chemical applications. Certified to NRTL C/US standards, it operates at 230V, 50-60Hz, and includes a UK/IN mains cable for regional compatibility.

Key Features:

  • Brand: Vacuubrand
  • Model: MD 4C NT +AK+EK
  • Stages: Three-stage diaphragm pump for stable, high vacuum
  • Voltage: 230V, 50-60Hz
  • Cable Type: UK/IN mains cable
  • Certification: NRTL C/US (North American safety standard)
  • Applications: Suitable for chemistry and analytical laboratory use

This vacuum system ensures chemical resistance, excellent performance stability, and reliable certification for global laboratories, especially those in the UK and India.

Downloads

Accessories

Vacuum tubings, PVC

ProductMaterialExt. ØMfr#Part#AvailabilityPrice
PVC15.9 mm206860604.714 081NTD 3,973
PVC34.9 mm206860634.714 084NTD 10,114
PVC38.1 mm206860654.714 085NTD 11,811
PVC15.9 mm206860614.714 082NTD 4,659
PVC22.3 mm206860624.714 083NTD 5,526

Compare similar models

Chemistry vacuum system, MD 4C NT +AK+EK, three stage, certification (NRTL): C/US, 230 V / 50-60 Hz, UK/IN mains cable

Manufacturer P/N

20736702

Part Number

4.670 506

Manufacturer

VACUUBRAND​

Plug type

UK

Chemistry diaphragm pump MD 4C NT AK+EK, three stage, CEE mains cable 230 V / 50-60 Hz

Manufacturer P/N

20736700

Part Number

9.880 837

Manufacturer

VACUUBRAND​

Plug type

EU

Chemistry diaphragm pump MD 4C NT AK+EK, three stage, CH mains cable 230 V / 50-60 Hz

Manufacturer P/N

20736701

Part Number

9.880 924

Manufacturer

VACUUBRAND​

Plug type

CH

Chemistry vacuum system MD 4C NT +AK+EK, three stage, certification (NRTL): C/US, 100-115 V/50-60 Hz, 120 V/60 Hz, US mains cable

Manufacturer P/N

20736703

Part Number

4.670 507

Manufacturer

VACUUBRAND​

Plug type

US

More items to explore

Chemistry Pumping Unit PC 3001 VARIO® select with condenser Peltronic®

ProductTypeDepthMfr#Part#AvailabilityPrice
PC 3001 VARIO ® select EKP300 mm207002454.669 248NTD 446,515

Diaphragm pumps chemistry design, ME 1C

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUME 1C207211009.880 934In stockNTD 51,146
UKME 1C207211029.880 936NTD 51,146
CHME 1C207211019.880 935NTD 51,146
USME 1C207211039.880 937NTD 51,146

Frequently asked questions

It is a high-performance three-stage diaphragm pump system designed for demanding chemical applications. Certified to NRTL C/US standards, it operates at 230V, 50-60Hz, and includes a UK/IN mains cable for regional compatibility.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story