Representative Image

SI Analytics pH Combination Electrodes N 6280, with Head Connection

Shaft length

Type

Specifications

Compare models
HS Code #
90279000
Connection plug
Plug head
Diaphragm
Ceramic
Electrolyte
KCl 3 mol/l
Shaft length
120 mm
Material shaft
Glass
Max. pH value
14
Max. temperature
100 °C
Min. pH value
0
Min. temperature
-5 °C
pH range
0 ... 14

NTD 16,326

Inc. VAT

Available soon

Product description

The SI Analytics pH Combination Electrodes N 6280, with Head Connection are high-performance laboratory electrodes designed for precise and reliable pH measurements. Featuring a glass shaft with a ceramic diaphragm and a spherical membrane, these electrodes ensure accurate readings across a wide pH range.

Key Features:

  • Brand: SI Analytics
  • Material: A-Glass shaft with ceramic diaphragm
  • Electrolyte: 3 mol/L KCl
  • Membrane: Spherical glass membrane
  • Temperature Range: -5°C to +100°C
  • pH Range: 0 to 14
  • Connection: Plug head
  • Reference System: Silamid
  • Product Overview: High-performance laboratory electrodes designed for precise and reliable pH measurements.

Ideal for demanding laboratory environments, the N 6280 electrodes offer exceptional durability and performance, ensuring consistent and accurate pH measurements.

Compare similar models

PH combination electrodes N 6280 with head connection

Manufacturer P/N

285100042

Part Number

9.041 117

Manufacturer

SI Analytics

Shaft length

120 mm

Electrode N 6180
Available soon
SI Analytics pH Combination Electrode N 6180

NTD 16,760

Inc. VAT

Manufacturer P/N

285100018

Part Number

9.041 180

Manufacturer

SI Analytics

Shaft length

170 mm

Frequently asked questions

It are high-performance laboratory electrodes designed for precise and reliable pH measurements. Featuring a glass shaft with a ceramic diaphragm and a spherical membrane, these electrodes ensure accurate readings across a wide pH range.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story