90278930
Connection plug
MultiPinTM plug head
Diaphragm
Hole
Electrolyte
Polymer
Shaft length
25 mm
Material shaft
Glass
Max. pH value
11
Max. temperature
80 °C
Min. pH value
1
Min. temperature
0 °C
pH range
1 ... 11

NTD 29,691

Inc. VAT

Supplier Stock: 4
Delivery: 2-4 weeks

Product description

The Mettler-Toledo pH-Electrode InLab Solids Pro-ISM is designed for precise pH measurement in solid and semi-solid samples. With a pH range of 1 to 11, this high-quality glass electrode ensures accurate and reliable readings. The 25 mm bole tip provides excellent sample contact, while the open connection design prevents clogging, making it ideal for applications in food, pharmaceutical, and environmental testing. Integrated Intelligent Sensor Management (ISM) technology enhances calibration and monitoring, ensuring ease of use and consistent performance.

Key Features:

  • Brand: Mettler-Toledo
  • Type: pH electrode for solid and semi-solid sample analysis
  • pH Range: 1...11 for accurate measurements
  • Material: High-quality glass body for durability and precision
  • Tip Size: Bole 25 mm for optimal sample contact
  • Connection: Open connection for enhanced measurement stability
  • Technology: Intelligent Sensor Management (ISM) for optimized calibration and monitoring
  • Application: Ideal for food, pharmaceutical, and environmental testing

Note: Cable - please order separately.

The Mettler-Toledo InLab Solids Pro-ISM pH Electrode is an essential tool for laboratories that require precise and reliable pH measurements in solid and semi-solid samples.

Accessories

Connection cables for electrodes with S7 plug head

ProductLengthConnection plugMfr#Part#AvailabilityPrice
1.2 mBNC302819159.041 613In stockNTD 4,515
1.2 mDIN302819199.041 634In stockNTD 5,021
1.2 m2 mm banana302819239.041 662NTD 4,985
1.2 m4 mm banana302819229.041 661NTD 4,985
5.0 m302819279.041 669NTD 7,296
1.2 mLemo302819259.041 664NTD 9,102
1.2 mBNC, watertight302819189.041 656NTD 4,985
10.0 m302819289.041 670NTD 8,886
3.0 m302819269.041 668NTD 5,057
5.0 mBNC302819179.041 654NTD 7,296
3.0 mBNC302819169.041 636NTD 5,743
3.0 mDIN302819209.041 657NTD 6,393
5.0 mDIN302819219.041 658NTD 8,524
1.2 mRCA302819249.041 663NTD 4,876

Compare similar models

pH-Electrode InLab® Solids Pro-ISM pH 1...11, glass bole 25 mm, open connection

Manufacturer P/N

51344155

Part Number

9.041 555

Manufacturer

Mettler-Toledo

Connection plug

MultiPinTM plug head

pH electrode InLab® Solids body length: 25 mm

Manufacturer P/N

51343153

Part Number

9.041 553

Manufacturer

Mettler-Toledo

Connection plug

S7 plug head

pH electrode InLab® Surface body length: 110 mm

Manufacturer P/N

51343156

Part Number

6.270 667

Manufacturer

Mettler-Toledo

Connection plug

BNC/RCA

Frequently asked questions

The pH electrode for solid and semi-solid sample analysis is designed for food, pharmaceutical, and environmental testing. This ph electrode for solid and semi-solid sample analysis format supports routine laboratory work in that application.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story