Representative Image

Macherey-Nagel CHROMABOND Columns SB, 3 mL, Sorbent Content 200 mg, PP, with PE Filter Elements, Pack of 50

Package

Package capacity

Specifications

Compare models
Base material
Silica gel
Endcapped
No
Filter element material
PE
Package
50 pcs
Package capacity
50 pcs
Particle size
45 µm
Particle type
Fully porous
pH stability
2 ... 8

NTD 13,906

Inc. VAT

Available soon

Product description

The Macherey-Nagel CHROMABOND Columns SB, 3 mL, Sorbent Content 200 mg, PP, with PE Filter Elements, Pack of 50 are designed for solid phase extraction applications requiring a strongly basic anion exchanger. Based on silica modified with quaternary amine, these SAX columns are suitable for the extraction of selected analytes such as organic acids, caffeine, and saccharin. Their polypropylene construction with PE filter elements supports reliable laboratory workflow and sample preparation performance.

Key Features:

  • Brand: Macherey-Nagel
  • Type: CHROMABOND SB SPE columns (SAX)
  • Volume: 3 mL
  • Sorbent Content: 200 mg
  • Material: PP with PE filter elements
  • Base Material: Silica
  • Pore Size: 60 Å
  • Particle Size: 45 µm
  • Specific Surface: 500 m²/g
  • pH Stability: 2 to 8
  • Function: Strongly basic anion exchanger with quaternary ammonium modified silica
  • Application: Recommended for organic acids, caffeine, and saccharin
  • Packaging: Pack of 50

These Macherey-Nagel CHROMABOND SB columns are a practical choice for laboratories requiring dependable SAX solid phase extraction for routine analytical workflows.

Downloads

Compare similar models

CHROMABOND columns SB volume: 3 ml, content of sorbent: 200 m g material: PP, with PE-filterelements pack of 50

Manufacturer P/N

730322

Part Number

4.003 580

Manufacturer

Macherey-Nagel

Package

50 pcs

CHROMABOND columns SB 6 ml pack of 30, 1000mg, PP with PE-filterelement

Manufacturer P/N

730323

Part Number

6.206 234

Manufacturer

Macherey-Nagel

Package

30 pcs

CHROMABOND Columns SB volume: 1 ml, content of sorbent: 100 mg material: PP, with PE-filterelements pack of 100

Manufacturer P/N

730078

Part Number

4.003 486

Manufacturer

Macherey-Nagel

Package

100 pcs

CHROMABOND columns SB volume: 6 ml, content of sorbent: 500 mg material: PP, with PE-filterelements pack of 30

Manufacturer P/N

730426

Part Number

4.003 614

Manufacturer

Macherey-Nagel

Package

30 pcs

CHROMABOND Columns SB volume: 3 ml, content of sorbent: 500 mg material: PP, with PE-filterelements pack of 50

Manufacturer P/N

730079

Part Number

7.075 759

Manufacturer

Macherey-Nagel

Package

50 pcs

Frequently asked questions

It are designed for solid phase extraction applications requiring a strongly basic anion exchanger. Based on silica modified with quaternary amine, these SAX columns are suitable for the extraction of selected analytes such as organic acids, caffeine, and saccharin. Their polypropylene construction with PE filter elements supports reliable laboratory workflow and sample preparation performance.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 13,906

Inc. VAT