Representative Image

KNF LIQUIPORT Diaphragm Liquid Pump U NF 1.300 TT.18S US-Plug - 115V/60HZ

Brand:KNF

Power supply frequency

Material head

Max. voltage

Power supply

Type

Specifications

Compare models
HS Code #
84135080
Depth
160 mm
Dimensions (WxDxH)
104 x 160 x 188 mm
Flow rate
500 ... 3,000 ml/min
Power supply frequency
60 Hz
Height
188 mm
Material head
PVDF
Max. voltage
115 V
Power supply
115 V, 60 Hz
Rated capacity
29 W
Type
U NF 1.300 TT.18 S

NTD 104,062

Inc. VAT

Available soon

Product description

The KNF LIQUIPORT Diaphragm Liquid Pump U NF 1.300 TT.18S with US-Plug (115V/60HZ) is a reliable and efficient pump designed for precise liquid transfer applications. Built with robust diaphragm technology, this pump ensures chemical resistance and long service life, making it ideal for laboratory, industrial, and medical use. Its compact design allows easy integration into various systems requiring dependable fluid handling.

Key Features:

  • Brand: KNF
  • Model: LIQUIPORT U NF 1.300 TT.18S
  • Voltage: 115V/60HZ with US-Plug
  • Technology: Diaphragm pump for chemical resistance and durability
  • Application: Suitable for liquid transfer in lab and industrial environments
  • Packaging: Sold as a single unit

KNF’s LIQUIPORT diaphragm pump delivers consistent performance and reliability for precise liquid handling needs.

Downloads

Compare similar models

LIQUIPORT® Diaphragm Liquid Pump U NF 1.300 TT.18S US-Plug - 115V/60HZ

Manufacturer P/N

U179109/153257

Part Number

4.686 771

Manufacturer

KNF

Power supply frequency

60 Hz

LIQUIPORT® Diaphragm Liquid Pump U NF 1.300 KT.18S US-Plug - 115V/60HZ

Manufacturer P/N

U179108/153257

Part Number

4.686 770

Manufacturer

KNF

Power supply frequency

60 Hz

LIQUIPORT® Diaphragm Liquid Pump U NF 1.300 FT.18S US-Plug - 115V/60HZ

Manufacturer P/N

U179110/153257

Part Number

4.686 772

Manufacturer

KNF

Power supply frequency

60 Hz

LIQUIPORT® Diaphragm Liquid Pump NF 1.300 FT.18 S, chemically-resistant

Manufacturer P/N

179110/153257

Part Number

6.274 069

Manufacturer

KNF

Power supply frequency

50/60 Hz

LIQUIPORT® Membrane liquid pump NF 1.300 TT.18 S Adjustable flow rate, PVDF pump head

Manufacturer P/N

179109/153257

Part Number

6.285 016

Manufacturer

KNF

Power supply frequency

50/60 Hz

Membrane liquid pump NF 1.300 KT.18 S, protection IP 65 capacity 0,5-3,0 (l/min), chemical resistant

Manufacturer P/N

179108/153257

Part Number

7.624 906

Manufacturer

KNF

Power supply frequency

50/60 Hz

More items to explore

Chemically-resistant Liquid Pumps LIQUIPORT® NF 1.100, external control

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
U NF 1.100 KT.18 RCMains connectionU179099/1532574.686 761NTD 75,310
NF 1.100 TT.18 RCMains connection179100/1532577.656 157NTD 56,130
U NF 1.100 TT.18 RCMains connectionU179100/1532574.686 762NTD 87,338
NF 1.100 FT.18 RCMains connection179101/1532577.643 011NTD 108,107
U NF 1.100 FT.18RCMains connectionU179101/1532574.686 763NTD 178,902
NF 1.100 KT.18 RCMains connection179099/1532576.323 498NTD 48,473

Frequently asked questions

It is a reliable and efficient pump designed for precise liquid transfer applications. Built with robust diaphragm technology, this pump ensures chemical resistance and long service life, making it ideal for laboratory, industrial, and medical use. Its compact design allows easy integration into various systems requiring dependable fluid handling.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story