Representative Image

IKA Orbital Shaker KS 130 Control S 3 with Positioning Point, with Swiss Plug

Brand:IKA

Max. voltage

Min. voltage

Plug type

Power supply

Specifications

Compare models
HS Code #
84798200
Depth
316 mm
Dimensions (WxDxH)
270 x 316 x 98 mm
Display
Digital
Power supply frequency
50/60 Hz
Height
98 mm
IP code
IP 21
Max. loading capacity
2 kg
Max. permitted ambient temp.
50 °C
Max. relative humidity rate
80 %
Max. speed
800 1/min

NTD 144,119

Inc. VAT

Available soon

Product description

The IKA Orbital Shaker KS 130 Control S 3 is designed for precise shaking in laboratory environments. Featuring a unique positioning point and a Swiss plug, this shaker ensures reliable and consistent performance. It is ideal for a wide range of laboratory applications requiring efficient mixing and shaking at controlled speeds.

Key Features:

  • Brand: IKA
  • Model: Orbital Shaker KS 130 Control S 3
  • Positioning: Positioning point for accurate placement
  • Plug: Swiss plug for compatibility with various outlets
  • Application: Ideal for laboratory shaking and mixing tasks

The IKA Orbital Shaker is an essential tool for laboratories that require efficient and reliable shaking for various applications.

Accessories

Clamps for IKA shakers and shaking incubators

ProductFor type of vesselsTypeMfr#Part#AvailabilityPrice
Erlenmeyer flasksAS 2.200012344009.838 092In stockNTD 2,601
Erlenmeyer flasksAS 2.100012343009.838 091In stockNTD 2,601
Erlenmeyer flasksAS 2.600038193006.237 536In stockNTD 4,840
Erlenmeyer flasksAS 2.300012345009.838 093NTD 2,601
Erlenmeyer flasksAS 2.400012346009.838 094NTD 4,840
Erlenmeyer flasksAS 2.500012347009.838 095NTD 4,840
Erlenmeyer flasksAS 2.700200164766.318 410NTD 5,815

Accessories for orbital shaker KS 130

ProductTypeDescriptionMfr#Part#AvailabilityPrice
AS 130.1Universal attachment00080173009.838 160NTD 25,465
AS 130.3Petri dish attachment00031200009.838 162NTD 8,488
AS 130.4Test tube holder00031203009.838 163NTD 17,265

Compare similar models

Orbital shaker KS 130 control S 3 with positioning point, with Swiss plug

Manufacturer P/N

0002980103

Part Number

4.008 029

Manufacturer

IKA

Max. voltage

240 V

Orbital shaker KS 130 control with positioning point
Available soon
IKA Orbital Shaker KS 130 Control, with Positioning Point

NTD 133,825

Inc. VAT

Manufacturer P/N

0002980100

Part Number

9.838 155

Manufacturer

IKA

Max. voltage

240 V

Orbital shaker KS 130 control S 2 with positioning point, with UK plug

Manufacturer P/N

0002980102

Part Number

4.008 028

Manufacturer

IKA

Max. voltage

240 V

Orbital shaker KS 130 control S 1 with positioning point, 115 V
Available soon
Orbital shaker KS 130 control S 1 with positioning point, 115 V

NTD 144,119

Inc. VAT

Manufacturer P/N

0002980101

Part Number

4.008 027

Manufacturer

IKA

Max. voltage

120 V

More items to explore

Vibrating shaker, VXR basic Vibrax®

ProductPlug typeTypeMfr#Part#AvailabilityPrice
UKVXR basic00028190026.202 467NTD 99,800
EUVXR basic00028190009.729 900NTD 92,684
CHVXR basic00028190036.240 796NTD 99,800
VXR basic00028190014.007 985NTD 99,800

Orbital shaker KS 501 digital

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUKS 501 digital00250029856.285 448NTD 270,719
UKKS 501 digital00250044516.490 888NTD 291,525
CHKS 501 digital00250044454.715 742NTD 291,525

Frequently asked questions

It is designed for precise shaking in laboratory environments. Featuring a unique positioning point and a Swiss plug, this shaker ensures reliable and consistent performance. It is ideal for a wide range of laboratory applications requiring efficient mixing and shaking at controlled speeds.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story