Representative Image

Hirschmann Mixing Cylinder 250 ml, Cl. A KB, Ring Section, Glass Stopper Duran, Blue Graduated

Division

Ground size

Height

Nominal capacity

Tolerance

Specifications

Compare models
Accuracy class
A
Colour
Clear
Colour graduation
Blue
Division
2.0 ml
Ground size
NS 29/32
Height
367 mm
Material
DURAN® glass
Material closure
Glass
Nominal capacity
250 ml
Tolerance
1,0 ± ml

NTD 3,612

Inc. VAT

Available soon

Product description

The Hirschmann Mixing Cylinder 250 ml, Cl. A, is designed for precise mixing and measurement in laboratory settings. Made from DURAN borosilicate glass, this cylinder features a KB (hexagonal base) for stability and a blue graduation for easy readability. The included glass stopper ensures secure containment during mixing. Ideal for applications that require accurate volume measurements and reliable performance in laboratory environments.

Key Features:

  • Brand: Hirschmann
  • Volume: 250 ml
  • Material: DURAN borosilicate glass
  • Accuracy: Cl. A with blue graduation
  • Base: KB (hexagonal base) for added stability
  • Stopper: Glass stopper included for secure containment
  • Application: Ideal for mixing and accurate measurement in lab environments

The Hirschmann Mixing Cylinder is an essential tool for laboratories that require precision and reliability in liquid handling tasks.

Compare similar models

Mixing cylinder 250 ml, class A KB, ring section, glass stopper Duran, blue graduated

Manufacturer P/N

2340286

Part Number

6.074 067

Manufacturer

Hirschmann

Division

2.0 ml

Mixing cylinder 50 ml, class A KB, ring section, glass stopper Duran, blue graduated

Manufacturer P/N

2340275

Part Number

7.614 647

Manufacturer

Hirschmann

Division

1.0 ml

Mixing cylinder 500 ml, class A KB, ring section, glass stopper Duran, blue graduated

Manufacturer P/N

2340290

Part Number

6.079 797

Manufacturer

Hirschmann

Division

5.0 ml

Mixing cylinder 10 ml, class A KB, ring section, glass stopper Duran, blue graduated

Manufacturer P/N

2340260

Part Number

6.266 951

Manufacturer

Hirschmann

Division

0.2 ml

Mixing cylinder 100 ml, class A KB, ring section, glass stopper Duran, blue graduated

Manufacturer P/N

2340280

Part Number

6.228 541

Manufacturer

Hirschmann

Division

1.0 ml

Mixing cylinder 2000 ml, class A KB, ring section, glass stopper Duran, blue graduated

Manufacturer P/N

2340294

Part Number

7.981 736

Manufacturer

Hirschmann

Division

20.0 ml

Mixing cylinder 25 ml, class A KB, ring section, glass stopper Duran, blue graduated

Manufacturer P/N

2340270

Part Number

6.233 392

Manufacturer

Hirschmann

Division

0.5 ml

Mixing cylinder 1000 ml, class A KB, ring section, glass stopper Duran, blue graduated

Manufacturer P/N

2340293

Part Number

7.981 735

Manufacturer

Hirschmann

Division

10.0 ml

More items to explore

Mixing cylinders, DURAN®, class A, blue graduated, with PE stopper

ProductType of closureType of graduationMfr#Part#AvailabilityPrice
NS stopperPrinted23401756.303 180NTD 1,734
NS stopperPrinted23401806.303 181NTD 1,878
NS stopperPrinted23401866.401 101NTD 2,817
NS stopperPrinted23401606.309 085NTD 1,481
NS stopperPrinted23401906.079 770NTD 4,479
NS stopperPrinted23401706.401 375NTD 1,589
NS stopperPrinted23401936.800 311NTD 6,177
NS stopperPrinted23401946.201 060NTD 9,572

Frequently asked questions

It is designed for precise mixing and measurement in laboratory settings. Made from DURAN borosilicate glass, this cylinder features a KB (hexagonal base) for stability and a blue graduation for easy readability. The included glass stopper ensures secure containment during mixing. Ideal for applications that require accurate volume measurements and reliable performance in laboratory environments.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 3,612

Inc. VAT

MoQ (2)x(2)