The Heidolph Scientific, Duomax 1030 (5° Tilt Angle) CH-Plug is a Duomax from Heidolph Scientific. The Rocking shaker Duomax is suitable for the modular Incubator 1000 and is recommended for applications which require variable temperatures. With 2-dimensional tilting movement, suitable for petri dishes, culture bottles, erlenmeyer flasks and all standard vessels
Key Features:
Brand: Heidolph Scientific
Type: Duomax
Temperature: An overtemperature sensor preventatively shuts off the unit in a dangerous heat-up situation, particularly valuable for you in case of continuous operation
Specification: Insulated drive system prevents any heat-up coming from the motor and consequently thermal damage to your sample
Speed: Designed with a low center of gravity which prevents gliding at high speed, even on a damp surface
Design: Set and continuously adjust the variable speed on the analog control knob, suitable for all standard vessels
Timer: An analog process timer (maximum. 120 minutes) allows for unattended operation. When the set time has elapsed, an acoustic alarm will sound and the operation stops
The Heidolph Scientific, Duomax 1030 (5° Tilt Angle) CH-Plug where this Duomax with An overtemperature sensor preventatively shuts off the unit in a dangerous heat-up situation, particularly valuable for you in case of continuous operation is required.
It is a Duomax from Heidolph Scientific. The Rocking shaker Duomax is suitable for the modular Incubator 1000 and is recommended for applications which require variable temperatures. With 2-dimensional tilting movement, suitable for petri dishes, culture bottles, erlenmeyer flasks and all standard vessels
Yes. It is designed for the modular Incubator 1000 and is recommended for applications which require variable temperatures, and offers duomax and an overtemperature sensor preventatively shuts off the unit in a dangerous heat-up situation, particularly valuable for you in case of continuous operation to support this kind of work.
It has duomax, an overtemperature sensor preventatively shuts off the unit in a dangerous heat-up situation, particularly valuable for you in case of continuous operation and insulated drive system prevents any heat-up coming from the motor and consequently thermal damage to your sample.
It offers a low center of gravity which prevents gliding at high speed, even on a damp surface, set and continuously adjust the variable speed on the analog control knob, suitable for all standard vessels, an analog process timer (maximum. 120 minutes) allows for unattended operation. When the set time has elapsed, an acoustic alarm will sound and the operation stops and an analog process timer (max. 120 min) allows for unattended operation. When the set time has elapsed, an acoustic alarm will sound and the operation stops.
Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.
Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.
A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.
Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.
Laboratory balances are essential weighing instruments used to measure samples, reagents, powders, chemicals and materials with accuracy and consistency. They are commonly used in research, education, quality control, pharmaceutical testing, food testing, industrial laboratories and general scientific workflows.