Product description

The BINDER ICH Light Module for KB PRO / KBF 260 and 470 converts standard climate and cooling incubators into fully compliant photostability testing chambers according to ICH Q1B. Equipped with dedicated VIS and UVA illumination cassettes, this module delivers controlled, uniform light exposure for stability testing of pharmaceuticals and other light-sensitive materials. It installs easily into compatible chambers and provides reliable, repeatable test conditions.

Key Features:

  • Brand: BINDER
  • Application: Designed for ICH Q1B photostability testing
  • Compatibility: KB PRO 260/470, KBF 260/470, KBF PRO 260/470
  • Lighting System: VIS and UVA cassettes for complete required spectral exposure
  • Control Options: Available in time-programmed or light-dose controlled (LQC) versions
  • Illumination Uniformity: Optimised for consistent intensity across the entire sample area
  • Compliance: Meets ICH Q1B requirements for VIS and UVA testing conditions
  • Installation: Includes mounting brackets, supply box, and connection cables
  • Durability: Robust cassette design for long operating life

Scope of Supply:

  • VIS light cassette with connection cable
  • UVA light cassette with connection cable
  • Power supply module / supply box
  • Mounting rails and installation hardware
  • For LQC version: VIS and UVA light-dose sensors
  • User manual

This BINDER ICH Light Module is a practical and cost-effective upgrade for laboratories performing photostability studies. It ensures controlled and repeatable light exposure in accordance with regulatory guidelines, making it ideal for pharmaceutical stability testing and quality assurance workflows.

Compare similar models

Light module ICH-Q1B

Manufacturer P/N

8012-2441

Part Number

4.710 131

Manufacturer

BINDER

Description

ICH light module

Light module ICH-Q1B

Manufacturer P/N

8012-2442

Part Number

4.710 132

Manufacturer

BINDER

Description

ICH light module

Light module ICH-Q1B with LQC

Manufacturer P/N

8012-2444

Part Number

4.710 134

Manufacturer

BINDER

Description

ICH light module with LQC

Light module ICH-Q1B with LQC

Manufacturer P/N

8012-2443

Part Number

4.710 133

Manufacturer

BINDER

Description

ICH light module with LQC

Frequently asked questions

The BINDER ICH Light Module for KB PRO / KBF 260 and 470 converts standard climate and cooling incubators into fully compliant photostability testing chambers according to ICH Q1B. Equipped with dedicated VIS and UVA illumination cassettes, this module delivers controlled, uniform light exposure for stability testing of pharmaceuticals and other light-sensitive materials. It installs easily into compatible chambers and provides reliable, repeatable test conditions.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story