Representative Image

Behr Infrared Rapid Sample Digestor with Manual Power Control InKjel 1225M for 12 x 250 ml Sample Vessels

Max. no. of sample positions

Type

Specifications

Compare models
Amperage
8 A
Power supply frequency
50/60 Hz
Height
750 mm
Max. no. of sample positions
12
Max. temperature
410 °C
Max. voltage
230 V·AC
Power supply
230 V·AC, 50/60 Hz , 8 A
Rated capacity
1500 W
Type
InKjel 1225 M
UNSPSC
41104815

NTD 233,624

Inc. VAT

Available soon

Product description

The Behr Infrared Rapid Sample Digestor InKjel 1225M is designed for efficient nitrogen determination using the Kjeldahl method. Accommodating 12 x 250 ml sample vessels, it features direct heating through high-quality quartz infrared radiators, reaching temperatures up to 830°C within one minute. The unit offers manually adjustable energy control, ensuring uniform heating and reliable results across all sample positions.

Key Features:

  • Brand: Behr
  • Model: InKjel 1225M
  • Sample Capacity: 12 x 250 ml vessels
  • Heating: Quartz infrared radiators (1500W) reaching 830°C in 1 minute
  • Energy Control: Manually adjustable power setting
  • Applications: Suitable for nitrogen determination in various industries including food, environmental, and pharmaceuticals
  • Included Components: Multi-level console, fume extraction unit, sample rack, and glass digestion vessels

This digestor is ideal for laboratories requiring rapid and precise sample digestion, offering flexibility and efficiency in analytical processes.

Accessories

Accessories for Kjeldahl rapid sample digestors

ProductTypeDescriptionMfr#Part#AvailabilityPrice
SR 3iSample vessel, 250ml, for InKjel*B002179599.843 766In stockNTD 3,251
SR 5Sample vessel 500ml, for K8 B*B003731709.843 751NTD 6,863
AFSAntifoam tabletsB002179369.843 753NTD 21,853
WPNitrogen-free weighing boatsB004411369.843 754NTD 2,926
KJ 500Sample vessel, 500ml, for InKjel*B002181959.843 775NTD 7,224
SR 4Sample vessel 100ml, for InKjel*B002179609.843 750NTD 2,348
EG 4/ 500Vessel holding frame for four 500ml vessels. Component of InKjel 450 M and PB002180859.843 790NTD 18,891
EG 12Vessel holding frame for twelve 250ml vessels. Component of InKjel 1225 M and PB002180879.843 789NTD 26,115
AE 4Fume exhaust manifold for InKjel 450 and 475 (M and P)B002180889.843 792NTD 38,251
EG 6Vessel holding frame for six 250ml vessels. Component of InKjel 625 M and PB002180869.843 788NTD 18,891
EG 4/ 750Vessel holding frame for four 750ml vessels. Component of InKjel 475 M and PB002180809.843 791NTD 19,107
KJ 750Sample vessel, 750ml, for InKjel*B002182189.843 776NTD 7,585
AE12Fume exhaust manifold for InKjel 1225 (M and P)B002180909.843 794NTD 61,440
AE 6Fume exhaust manifold for InKjel 625 (M and P)B002180899.843 793NTD 40,021

Compare similar models

Infrared rapid sample digestor with manual power control InKjel 1225M for 12x250ml sample vessels

Manufacturer P/N

B00218103

Part Number

9.843 771

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

12

Rapid infrared digestion unit InKjel 1210 M for 12 sample vessels of 100 ml

Manufacturer P/N

B00373235

Part Number

9.843 757

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

12

Infrared rapid sample digestor InKjel 450 M with manual power control, for 4x500ml sample vessels

Manufacturer P/N

B00218067

Part Number

9.843 768

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

4

Infrared rapid sample digestor InKjel 475 M with manual power sontrol, for 4x750ml sample vessels

Manufacturer P/N

B00218068

Part Number

9.843 769

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

4

Infrared rapid sample digestor with manual power control InKjel 625M for 6x250ml sample vessels

Manufacturer P/N

B00218101

Part Number

9.843 770

Manufacturer

Behr Labor-Technik

Max. no. of sample positions

6

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 233,624

Inc. VAT