Representative Image

2mag Magnetic Stirring System MIXdrive 6, External Control (Control Unit Ordered Separately)

Brand:2mag

No. of stirring positions

Stirring capacity per position

Stirring centre distances

Type

Weight

Specifications

Compare models
HS Code #
84798200
Depth
375 mm
Dimensions (WxDxH)
245 x 375 x 38 mm
Height
38 mm
IP code
IP 68
Material housing
Stainless steel
Max. voltage
48 V·DC
No. of stirring positions
6
Package capacity
1 ml
Power supply
48 V·DC
Rated capacity
40 W

NTD 63,102

Inc. VAT

Available soon

Product description

The 2mag Magnetic Stirring System MIXdrive 6, External Control, is designed for reliable and precise stirring in laboratory applications. Built for flexible operation, this system supports controlled stirring performance across a range of laboratory processes. When paired with a compatible external control unit, the MIXdrive 6 allows users to configure operation to suit specific application requirements. It is also suitable for demanding environments, with a permissible ambient temperature range in air and water from -10 to 50 °C.

Key Features:

  • Brand: 2mag
  • Model: MIXdrive 6
  • System Type: Magnetic stirring system with external control
  • Application: Suitable for laboratory stirring applications requiring reliable and adjustable control
  • Ambient Temperature Range: Permissible ambient temperature in air and water from -10 to 50 °C

Note: Control unit must be ordered separately.

The 2mag Magnetic Stirring System MIXdrive 6, External Control, is a practical choice for laboratories seeking dependable stirring performance with flexible external control. Its broad ambient temperature tolerance and adaptable configuration make it suitable for a variety of research and process applications.

Downloads

Accessories

Control unit MIXcontrol 40

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EUMIXcontrol 40904009.645 971NTD 55,516

Accessories for mixer MIXdrive

ProductTypeDescriptionMfr#Part#AvailabilityPrice
mixBATH PCBath vessel, PC, up to 50 °C408506.286 233NTD 35,109
mixBATHcover 15Bath lid, PP408156.255 612NTD 20,841
mixBATHcover 6Bath lid, PP408067.639 439NTD 20,841
distriBOX 44-way distributor490049.645 972NTD 16,001
distriBOX 88-way distributor490089.645 973NTD 22,611
mixBATHBath vessel, stainless steel, electropolished409509.645 974NTD 44,175

Compare similar models

Magnetic stirring system MIXdrive 6 external control -Please order control unit separately-

Manufacturer P/N

40006

Part Number

9.645 963

Manufacturer

2mag

No. of stirring positions

6

Magnetic stirirng system MIXdrive 15 external control -Please order control unit separately-

Manufacturer P/N

40015

Part Number

9.645 965

Manufacturer

2mag

No. of stirring positions

15

Magnetic stirring system MIXdrive 60 external control -Please order control unit separately-

Manufacturer P/N

40060

Part Number

9.645 967

Manufacturer

2mag

No. of stirring positions

60

Frequently asked questions

It is designed for reliable and precise stirring in laboratory applications. Built for flexible operation, this system supports controlled stirring performance across a range of laboratory processes. When paired with a compatible external control unit, the MIXdrive 6 allows users to configure operation to suit specific application requirements. It is also suitable for demanding environments, with a permissible ambient temperature range in air and water from -10 to 50 °C.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story