Specifications

Depth
126 mm
Dimensions (WxDxH)
152 x 126 x 108 mm
Height
108 mm
IP code
IP 40
Max. measured value
1080 mbar
Max. permitted ambient temp.
40 °C
Measured range
0.1 ... 1,080 mbar
Min. measured value
0.1 mbar
Min. permitted ambient temperature
10 °C
Type
VACUU·SELECT®

NTD 127,034

Inc. VAT

Available soon

Product description

The VACUUBRAND VACUU·SELECT Complete Controller, built-in version, with solenoid valve, PVDF/fluoroplastics, 100-230 V / 50-60 Hz, plug CEE/CH/UK/US/AUS/CN is a vacuum controller from VACUUBRAND designed for monitoring and controlling vacuum processes. Scope of supply: Vacuum controller VACUU·SELECT® with vacuum valve, check valve, integrated ceramic vacuum sensor, venting valve and power supply. Its documented configuration includes electrical supply: 100-230 V, 50-60 Hz, and material: PVDF, Fluoroplastics.

Key Features:

  • Brand: VACUUBRAND
  • Product Type: Vacuum Controller
  • Electrical Supply: 100-230 V, 50-60 Hz
  • Material: PVDF, Fluoroplastics
  • Included Items: Vacuum controller VACUU·SELECT® with vacuum valve, check valve, integrated ceramic vacuum sensor, venting valve and power supply

The VACUUBRAND VACUU·SELECT Complete Controller, built-in version, with solenoid valve, PVDF/fluoroplastics, 100-230 V / 50-60 Hz, plug CEE/CH/UK/US/AUS/CN supports monitoring and controlling vacuum processes where the stated configuration is required. Confirm process compatibility, wetted materials, electrical supply, connections, and included components before ordering.

Accessories

Accessories for Vacuum Controller VACUU·SELECT and Measuring instrument DCP 3000

ProductDescriptionUNSPSCMfr#Part#AvailabilityPrice
Extension cable for VACUU·BUS®, 2m40151502206125529.882 853NTD 2,745
Liquid level sensor for VACUUBRAND catchpot 500 ml40151502206999089.882 848NTD 27,343
Y-adapter for VACUU·BUS ®40151502206832406.284 162NTD 8,488
Extension cable VACUU·BUS®, 4-pol., 10 m40151502226184936.252 487NTD 8,560
VACUU·BUS® wall feedthrough (plug-socket), for wall thickness of 1 - 10 mm40151502206361534.669 820NTD 6,177
Digital-I/O-Module VACUU·BUS®40151502206362284.669 827NTD 18,385
Analog-I/O-Module VACUU·BUS®40151502206362294.661 327NTD 19,396
VMS-B module for vacuum controller CVC 3000 to switch a vacuum pump40151502206760307.940 071NTD 29,510

Accessories for Vacuum Controller VACUU·SELECT and Measuring instrument DCP 3000

ProductTypeDescriptionMfr#Part#AvailabilityPrice
VKW-BCooling water valve VKW-B206742209.882 852NTD 18,385
VBM-BAir admittance valve VBM-B206742179.882 849NTD 20,408
VV-B 6CSolenoid inline valve VV-B 6C206742919.882 851NTD 36,264
VV-B 6Solenoid inline valve VV-B 6206742906.239 120NTD 19,360
VV-B 15CSolenoid inline valve VV-B 15C with KF DN 25206742156.231 611NTD 48,184
VV-B 15CSolenoid inline valve VV-B 15C with KF DN 16206742104.670 300NTD 47,173

More items to explore

Compact Vacuum Controller VACUU·SELECT®, benchtop version

ProductTypeDepthMfr#Part#AvailabilityPrice
VACUU·SELECT®127 mm207000704.662 221NTD 127,540

Vacuum Controller VACUU·SELECT

ProductPlug typeTypeMfr#Part#AvailabilityPrice
EU/UK/CH/US/AUSVACUU·SELECT207000004.662 426NTD 87,880

Frequently asked questions

It is a vacuum controller from VACUUBRAND designed for monitoring and controlling vacuum processes. Scope of supply: Vacuum controller VACUU·SELECT® with vacuum valve, check valve, integrated ceramic vacuum sensor, venting valve and power supply.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

1 min read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

1 min read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

1 min read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

1 min read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story

NTD 127,034

Inc. VAT