Representative Image

VACUUBRAND ATEX Chemical Membrane Pump MV 10C EX, VARIO Four-stage, 230V / 50HZ

Specifications

HS Code #
84141089
Connection pressure side
KF DN 16
Connection suction side
KF DN 25
Depth
457 mm
Dimensions (WxDxH)
560 x 457 x 410 mm
Flow rate
8.1 m³/h
Power supply frequency
50 Hz
Height
410 mm
IP code
IP 54
Max. permitted ambient temp.
40 °C
Max. voltage
230 V

NTD 1,121,815

Inc. VAT

Available soon

Product description

The VACUUBRAND ATEX chemical Diaphragm Pump MV 10C EX VARIO four-stage, 230 V / 50 Hz is a diaphragm vacuum pump from VACUUBRAND designed for oil-free evacuation and pumping of gases or vapours. With the ATEX VARIO ® chemical diaphragm pumps, the vacuum can be precisely controlled by adjusting the motor speed. Its documented configuration includes electrical supply: 230 V, 50 Hz, pump design: Four-Stage, and chemical resistance: High chemical resistance and oil-free operation.

Key Features:

  • Brand: VACUUBRAND
  • Model: MV 10C EX
  • Product Type: Diaphragm Vacuum Pump
  • Electrical Supply: 230 V, 50 Hz
  • Pump Design: Four-Stage
  • Chemical Resistance: High chemical resistance and oil-free operation
  • Ignition Source Prevention: The absence of sliding surfaces ensures that ignition sources are avoided
  • Vacuum Control: Short process times thanks to hysteresis-free VARIO ® vacuum control; With the ATEX VARIO ® chemical diaphragm pumps, the vacuum can be precisely controlled by adjusting the motor speed
  • Demand-Based Operation: The pump runs only as fast as necessary, according to demand: minimal power consumption, extended maintenance intervals, quiet operation
  • External Control: The pump is driven by an additional control signal line
  • Vacuum Controller Option: The optional vacuum controller VACUU·SELECT, with an ATEX vacuum sensor and Connection Box 100, enables fully automatic evaporation without the need for parameter setting or user programming
  • Adaptive Vacuum Control: With the adaptive control, it finds the boiling pressure indepentently and adjusts the vacuum continuously and optimally according to the vapour pressure
  • ATEX Compliance: ATEX compliance:
  • Pumping Chamber Classification: Pumping chamber (gases pumped): II 2G Ex h IIC T3 Gb X
  • External Area Classification: External area (pump surroundings): II 2G Ex h IIB T4 Gb X (with inert gas purging) / II 3G Ex h IIB T4 Gc X (without inert gas purging)
  • Motor Classification: Motor: II 2G Ex db IIB T4 Gb

The VACUUBRAND ATEX chemical Diaphragm Pump MV 10C EX VARIO four-stage, 230 V / 50 Hz supports oil-free evacuation and pumping of gases or vapours where the stated configuration is required. Confirm process compatibility, wetted materials, electrical supply, connections, and included components before ordering.

More items to explore

Chemistry Diaphragm Vacuum Pump MZ 2C EX with ATEX compliance

ProductPlug typeTypeMfr#Part#AvailabilityPrice
stranded wireMZ 2C EX206969206.204 334NTD 304,925

Frequently asked questions

It is a diaphragm vacuum pump from VACUUBRAND designed for oil-free evacuation and pumping of gases or vapours. With the ATEX VARIO ® chemical diaphragm pumps, the vacuum can be precisely controlled by adjusting the motor speed.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story