Representative Image

Thistle Scientific omniPAGE Mini 100x100 mm Clamp Version with Glass Plates, 1 mm Bonded Spacers, 2 x 12 1 mm Sample Combs, and Cooling Pack

Specifications

HS Code #
90272000
Depth gel
85 mm
Depth
130 mm
Dimensions (WxDxH)
190 x 130 x 150 mm
Gel (WxD)
80 x 85 mm
Height
150 mm
Max. number of gels
4
Max. number of samples
80
Nominal capacity
1200 ml
Type
omniPAGE Mini
UNSPSC
41105340

NTD 33,700

Inc. VAT

Available soon

Product description

The Thistle Scientific omniPAGE Mini 100x100 mm Clamp Version is designed for efficient and precise protein electrophoresis applications. This compact system allows for the separation of up to four gels simultaneously, accommodating 20 samples per gel. It features a vertical chamber with platinum electrodes, ensuring consistent and reliable performance. The included glass plates come with bonded 1 mm thick spacers, providing optimal gel thickness for accurate results. Additionally, the system includes two 12-sample combs, a cooling pack for temperature regulation, and a dummy plate for safe storage and transport.

Key Features:

  • Brand: Thistle Scientific
  • Gel Dimensions: 100x100 mm
  • Number of Gels: Up to 4
  • Sample Capacity per Gel: 20 samples
  • Spacer Thickness: 1 mm
  • Includes: Glass plates with bonded spacers, 2 x 12 1 mm sample combs, cooling pack, and dummy plate
  • Application: Suitable for SDS-PAGE, native PAGE, gradient gels, and nucleic acid separation
  • Buffer Volume: 250–1200 mL
  • Dimensions (W x D x H): 19 x 13 x 15 cm

This system is an essential tool for electrophoresis procedures, ensuring consistent and accurate sample results.

Downloads

Accessories

Accessories for Electrophoresis Tank OmniPage Mini

ProductDescriptionDepthMfr#Part#AvailabilityPrice
Notched glass plates with bonded spacers (1 mm)10 cmVS10NGS16.229 252NTD 4,407
Notched glass plates (2 mm)10 cmVS10NG6.229 282NTD 2,709
Plain glass plates with bonded spacers (1 mm)10 cmVS10PGS16.230 607NTD 3,323
Plain glass plates (2 mm)10 cmVS10PG6.239 746NTD 2,059
Plain glass plates with bonded spacers (0.75 mm)10 cmVS10PGS0.759.584 730NTD 3,142
Notched glass plates with bonded spacers (1.5 mm)10 cmVS10NGS1.57.673 354NTD 4,407
Plain glass plates with bonded spacers (1.5 mm)10 cmVS10PGS1.59.584 731NTD 3,937
Notched glass plates with bonded spacers (0.75 mm)10 cmVS10NGS0.756.229 789NTD 4,407

Combs MC for Electrophoresis Tank OmniPage Mini

ProductMax. volume sampleNo. of samplesMfr#Part#AvailabilityPrice
25 µl16VS10-16MC-16.229 039NTD 2,709
20 µl16VS10-16MC-0.759.584 733NTD 2,709
40 µl16VS10-16MC-1.59.584 735NTD 2,709
60 µl8VS10-8MC-16.232 797NTD 2,709
120 µl8VS10-8MC-26.232 066NTD 2,709

Frequently asked questions

It is designed for efficient and precise protein electrophoresis applications. This compact system allows for the separation of up to four gels simultaneously, accommodating 20 samples per gel. It features a vertical chamber with platinum electrodes, ensuring consistent and reliable performance. The included glass plates come with bonded 1 mm thick spacers, providing optimal gel thickness for accurate results. Additionally, the system includes two 12-sample combs, a cooling pack for temperature regulation, and a dummy plate for safe storage and transport.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story