Representative Image

Thermo Kendro Digital Platform Rocker (230V, EU/UK/CHN Plug)

Specifications

HS Code #
84798200
Depth
390 mm
Depth moving table
322 mm
Dimensions (WxDxH)
292 x 390 x 206 mm
Power supply frequency
50/60 Hz
Height
206 mm
Inclination angle
1 ... 45 °
Max. inclination angle
45 °
Max. loading capacity
8 kg
Max. permitted ambient temp.
40 °C
Max. relative humidity rate
85 %

NTD 64,944

Inc. VAT

Available soon

Product description

The Thermo Kendro Digital Platform Rocker is a precision laboratory shaker designed for gentle and consistent mixing of samples. Ideal for applications such as hybridization, blotting, and staining or destaining gels, this rocker ensures uniform agitation with minimal sample disruption.

Key Features:

  • Brand: Thermo Kendro
  • Speed Range: 1 to 70 rpm
  • Speed Accuracy: ±1 rpm at ≤50 rpm; ±2 rpm at >50 rpm
  • Adjustable Rocking Angle: 1° to 48° (±24°)
  • Timer Range: Continuous or 1 second to 9999 minutes
  • Maximum Load Capacity: 8 kg
  • Platform Dimensions: 19.2 x 15.3 x 13.9 cm
  • Power Supply: 230V, 50/60 Hz
  • Plug Type: EU/UK/CHN compatible

Note: Optionally, another platform can be added for a 2-tier structure. Please order separately.

Enhance your laboratory's efficiency with the Thermo Kendro Digital Platform Rocker, providing reliable and consistent results for various laboratory applications.

Accessories

Accessories for Digital platform rocker

ProductDescriptionUNSPSCMfr#Part#AvailabilityPrice
Platform with 6 screws41103816888821484.683 673NTD 6,285
Platform stacking bars with 4 screws41103816888821614.683 674NTD 4,804

Frequently asked questions

It is a precision laboratory shaker designed for gentle and consistent mixing of samples. Ideal for applications such as hybridization, blotting, and staining or destaining gels, this rocker ensures uniform agitation with minimal sample disruption.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story