Representative Image

Testo Temperature Data Logger 175 T3, with 2 External Sensor Connections

Brand:Testo

Specifications

HS Code #
90251900
Battery/ rechargeable battery
3 x AAA
Colour
Black
Depth
29 mm
Designation ANSI
AAA
Dimensions (WxDxH)
54 x 29 x 96 mm
Disposable
No
Height
96 mm
IP code
IP 65
Max. measuring cycle
24 h
Measuring cycle
10 sec ... 24 h

NTD 15,170

Inc. VAT

Available soon

Product description

The Testo Temperature Data Logger 175 T3 is a reliable device designed for accurate temperature monitoring with two external sensor connections. It is ideal for applications requiring simultaneous measurement of multiple points, offering flexibility and precision for laboratory, storage, and transport environments.

Key Features:

  • Brand: Testo
  • Sensor Connections: Two external sensor inputs for versatile temperature monitoring
  • Sensor Types: Compatible with Type T and Type K temperature sensors
  • Application: Suitable for labs, warehouses, cold storage, and transportation monitoring
  • Durability: Robust design suitable for rough environmental conditions
  • Protection: Splash- and jet-water resistant
  • Temperature Range: Measures from -50 to +1000 °C with appropriate sensors
  • Display: Easy-to-read LCD screen
  • Data Logging: High-capacity memory for 1 million readings
  • Battery Life: Up to 3 years of operation
  • Interfaces: Mini USB and SD card slot for data transfer
  • Software: Free download available for data readout and analysis
  • Data Security: Measurements retained even when battery is changed or depleted

Scope of Supply:

  • Temperature data logger with 2 connections for external temperature sensors Type T and Type K
  • Wall bracket
  • Lock
  • Batteries
  • Calibration protocol

Ensure precise multi-point temperature measurement with the Testo 175 T3 data logger, built for durability and high-performance monitoring.

Downloads

Accessories

Accessories for testo data loggers 174 / 175 / 176 / 184

ProductDescriptionForMfr#Part#AvailabilityPrice
Software ComSoft Professionaltesto 174/175/176/184055417047.658 589NTD 24,851
Software ComSoft 21 CFR Part 11testo 174/175/176/184055417056.254 452NTD 89,830
USB interfacetesto 174057205007.940 031NTD 7,441
USB connection cabletesto 175/176044900476.243 794NTD 2,384
SD memory card, 2 GBtesto 175/176055488036.253 413NTD 2,709
Wall bracket with locktesto 175055417027.611 480NTD 2,420
Battery type Micro LR03 (AAA), 1.5 Vtesto 175051500096.251 430NTD 253
Wall bracket with locktesto 176055417036.325 789NTD 2,420

Thermocouples with TC adapter for testo measuring instruments

ProductType of probeMax. temperatureMfr#Part#AvailabilityPrice
Type K400 °C060206449.851 724NTD 1,914
Type K250 °C060206467.036 711NTD 2,998
Type K400 °C060206457.036 710NTD 2,926

More items to explore

Temperature logger testo 175 T1

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
testo 175 T1Battery057217516.243 856NTD 10,366

Temperature logger testo 175 T2

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
testo 175 T2Battery057217526.244 052NTD 12,859

Frequently asked questions

It is a reliable device designed for accurate temperature monitoring with two external sensor connections. It is ideal for applications requiring simultaneous measurement of multiple points, offering flexibility and precision for laboratory, storage, and transport environments.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story