Brand:Lovibond

Specifications

HS Code #
90278930
Accuracy temperature
±0.2 °C
Accuracy temperature
0.2 °C
Battery/ rechargeable battery
4 x AA
Intake capacity
0 ... 50 mg/l
Concentration accuracy
±0.1 mg/l (0 ... 20 mg/l)/±10 % (>20 mg/l)
Concentration resolution
0.01 mg/l
Depth
162 mm
Designation ANSI
AA
Dimensions (WxDxH)
98 x 162 x 54 mm
Height
54 mm

NTD 62,740

Inc. VAT

Available soon

Product description

Lovibond SD 400 OXI L (Set 2) is an advanced solution for precise oxygen measurement in a variety of applications. This set includes the optical oxygen sensor with a 3-meter cable for added flexibility, batteries for immediate use, and a storage/calibrating bottle for easy maintenance and accurate calibration. Ideal for laboratory, industrial, and environmental settings, this set ensures reliable and consistent oxygen level readings. Whether you're monitoring oxygen levels in research, manufacturing, or environmental analysis, the SD 400 OXI L (Set 2) provides everything needed for optimal performance.

Key Features:

  • Brand: Lovibond
  • Oxygen Sensor: High-precision optical oxygen sensor for reliable measurements
  • Cable Length: 3 meters for increased flexibility in various setups
  • Included Accessories: Batteries for immediate use and a storage/calibrating bottle for easy calibration and protection
  • Application: Perfect for laboratory, industrial, and environmental oxygen monitoring
  • Technology: Luminescence technology provides especially high measuring accuracy
  • Response Time: Short response time of the oxygen probe
  • Maintenance: Low maintenance thanks to long-lasting oxygen probe and membrane head; no electrolyte solution required
  • Operation: No inflow required; stirrers or manual stirring are no longer necessary
  • Software: Includes software for extended and simplified data management with data logger function
  • Display: Backlit LC display for clear readings in dark environments

Scope of Supply:

  • SD 400 Oxi L (Set 1): Meter with 4 (AA) batteries, optical oxygen probe with 1.5 m cable, storage/calibration bottle, micro SD card with calibration data, software and manual (on Micro SD card), short manual, lanyard, and case
  • SD 400 Oxi L (Set 2): As Set 1 but with optical oxygen probe with 3 m cable
  • SD 400 Oxi L (Set 3): As Set 2 but with optical oxygen probe with 10 m cable

Lovibond SD 400 OXI L (Set 2) is a comprehensive and reliable instrument for professionals needing accurate oxygen monitoring with flexible probe length options and practical accessories.

Accessories

Optical oxygen sensor for Oxygen meter SD 400 Oxi

ProductIntake capacityMax. temperatureMfr#Part#AvailabilityPrice
0 ... 50 mg/l50 °C7400706.288 683NTD 37,854
0 ... 50 mg/l50 °C7400806.288 684NTD 35,434
0 ... 50 mg/l50 °C7400606.288 682NTD 34,314

More items to explore

Oxygen meter SD 400 Oxi L

ProductTypeType of auxiliary energyMfr#Part#AvailabilityPrice
SD 400 Oxi LBattery7400306.288 681NTD 33,050

Frequently asked questions

Lovibond SD 400 OXI L (Set 2) is an advanced solution for precise oxygen measurement in a variety of applications. This set includes the optical oxygen sensor with a 3-meter cable for added flexibility, batteries for immediate use, and a storage/calibrating bottle for easy maintenance and accurate calibration. Ideal for laboratory, industrial, and environmental settings, this set ensures reliable and consistent oxygen level readings. Whether you're monitoring oxygen levels in research, manufacturing, or environmental analysis, the SD 400 OXI L (Set 2) provides everything needed for optimal performance.

Insights

Explore
Cleaning Lab Glassware: Removing Stubborn Residue

7 mins read

Cleaning Lab Glassware: Removing Stubborn Residue

Cleaning laboratory glassware properly is essential for accurate, safe, and repeatable lab work. This guide explains how to remove stubborn residue from beakers, flasks, bottles, volumetric glassware, and other lab glassware, including grease, dried salts, biological residue, stains, and burnt deposits. It also covers safe cleaning methods, common mistakes, drying and storage tips, and when damaged glassware should be replaced.

Read full story
How to Calibrate Your Pipettes to ISO 8655 Standards

7 mins read

How to Calibrate Your Pipettes to ISO 8655 Standards

Pipette calibration helps laboratories confirm that liquid handling results remain accurate, repeatable, and traceable. This guide explains how pipettes are calibrated to ISO 8655 standards, including gravimetric testing, environmental control, correct tip selection, volume testing, calibration records, and common mistakes to avoid. It also covers when to use in-house calibration and when an external calibration service may be more suitable.

Read full story
Molarity and Dilution Calculator

9 mins read

Molarity and Dilution Calculator

A free molarity and dilution calculator covering four essential lab calculations: C1V1=C2V2 dilution (solve for any unknown), molarity from mass, mass from molarity, and serial dilution table generation. Includes worked examples, a concentration units guide and step-by-step preparation instructions for every result.

Read full story
Buffer Preparation Calculator

9 mins read

Buffer Preparation Calculator

Free online buffer preparation calculator. Select your buffer system, enter target pH, concentration and volume, and get an exact lab-ready recipe with reagent masses and step-by-step instructions. Covers PBS, Tris-HCl, sodium phosphate, acetate, HEPES, MOPS and more.

Read full story